Relined fiberglass post: an ex vivo study of the resin cement thickness and dentin-resin interface
- PMID: 27556553
- DOI: 10.1590/1807-3107BOR-2016.vol30.0077
Relined fiberglass post: an ex vivo study of the resin cement thickness and dentin-resin interface
Abstract
The aim of this study was to evaluate the thickness of resin cements in the root thirds when using conventional fiberglass posts (CP) and relined fiberglass posts (RP) in weakened roots and to evaluate the morphological characteristics of the dentin-resin interface. Forty human maxillary anterior teeth had the crown sectioned below the cemento-enamel junction. The canals were endodontically treated and weakened with diamond burs. Teeth were divided into four groups (n = 10): Group 1 - CP + RelyX ARC; Group 2 - CP + RelyX U200; Group 3 - RP + RelyX ARC; and Group 4 - RP + RelyX U200. Prior to luting, 0.1% Fluorescein and 0.1% Rhodamine B dyes were added to an adhesive and resin cement, respectively. Slices were obtained from the apical, middle, and cervical thirds of the root. Confocal laser scanning microscopy images were recorded in four areas (buccal, lingual, mesial, distal) of each third. In each area, four equidistant measures of the resin cement were made and the mean value was calculated. The interface morphology was observed. The data were submitted to three-way ANOVA and Tukey's test (α = 0.05). The interaction between fiberglass posts, resin cement, and root thirds was significant (p < 0.0001). The resin cement thicknesses were significantly lower for RP in comparison with CP, except in the apical third. There was no significant difference between the resin cements for RP. There was formation of resin cement tags and adhesive tags along the root for RP. RP favored the formation of thin and uniform resin cement films and resin tags in weakened roots.
Similar articles
-
Longevity of bond strength of resin cements to root dentine after radiation therapy.Int Endod J. 2018 Nov;51(11):1301-1312. doi: 10.1111/iej.12945. Epub 2018 May 21. Int Endod J. 2018. PMID: 29729026
-
Influence of 2% chlorhexidine digluconate on bond strength of a glass-fibre post luted with resin or glass-ionomer based cement.J Dent. 2014 Jun;42(6):735-41. doi: 10.1016/j.jdent.2014.02.019. Epub 2014 Mar 5. J Dent. 2014. PMID: 24613604
-
Influence of resin cement and post configuration on bond strength to root dentine.Int Endod J. 2012 Feb;45(2):136-45. doi: 10.1111/j.1365-2591.2011.01953.x. Epub 2011 Oct 13. Int Endod J. 2012. PMID: 21995296 Clinical Trial.
-
Influence of Relining Post on the Bond Strength of Resin Cements.J Contemp Dent Pract. 2015 Jul 1;16(7):559-64. doi: 10.5005/jp-journals-10024-1722. J Contemp Dent Pract. 2015. PMID: 26329411
-
Effect of luting cement and thermomechanical loading on retention of glass fibre posts in root canals.J Dent. 2014 Jan;42(1):75-83. doi: 10.1016/j.jdent.2013.10.017. Epub 2013 Nov 4. J Dent. 2014. PMID: 24200871
Cited by
-
Effects of a relined fiberglass post with conventional and self-adhesive resin cement.Restor Dent Endod. 2024 Mar 27;49(2):e18. doi: 10.5395/rde.2024.49.e18. eCollection 2024 May. Restor Dent Endod. 2024. PMID: 38841382 Free PMC article.
-
Effect of aging and cementation systems on the bond strength to root dentin after fiber post cementation.Braz Dent J. 2023 Jan-Feb;34(1):52-60. doi: 10.1590/0103-6440202305082. Braz Dent J. 2023. PMID: 36888845 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous