Accuracy of Percutaneous Lumbosacral Pedicle Screw Placement Using the Oblique Fluoroscopic View Based on Computed Tomography Evaluations
- PMID: 27559441
- PMCID: PMC4995244
- DOI: 10.4184/asj.2016.10.4.630
Accuracy of Percutaneous Lumbosacral Pedicle Screw Placement Using the Oblique Fluoroscopic View Based on Computed Tomography Evaluations
Abstract
Study design: Retrospective.
Purpose: This study aims to investigate the accuracy of the oblique fluoroscopic view, based on preoperative computed tomography (CT) images for accurate placement of lumbosacral percutaneous pedicle screws (PPS).
Overview of literature: Although PPS misplacement has been reported as one of the main complications in minimally invasive spine surgery, there is no comparative data on the misplacement rate among different fluoroscopic techniques, or comparing such techniques with open procedures.
Methods: We retrospectively selected 230 consecutive patients who underwent posterior spinal fusion with a pedicle screw construct for degenerative lumbar disease, and divided them into 3 groups, those who had undergone: minimally invasive percutaneous procedure using biplane (lateral and anterior-posterior views using a single C-arm) fluoroscope views (group M-1), minimally invasive percutaneous procedure using the oblique fluoroscopic view based on preoperative CT (group M-2), and conventional open procedure using a lateral fluoroscopic view (group O: controls). The relative position of the screw to the pedicle was graded for the pedicle breach as no breach, <2 mm, 2-4 mm, or >4 mm. Inaccuracy was calculated and assessed according to the spinal level, direction and neurological deficit. Inter-group radiation exposure was estimated using fluoroscopy time.
Results: Inaccuracy involved an incline toward L5, causing medial or lateral perforation of pedicles in group M-1, but it was distributed relatively equally throughout multiple levels in groups M-2 and controls. The mean fluoroscopy time/case ranged from 1.6 to 3.9 minutes.
Conclusions: Minimally invasive lumbosacral PPS placement using the conventional fluoroscopic technique carries an increased risk of inaccurate screw placement and resultant neurological deficits, compared with that of the open procedure. Inaccuracy tended to be distributed between medial and lateral perforations of the L5 pedicle, as a result of pedicle morphology and the PPS pathway. Oblique fluoroscopic views, based on CT measurement, may allow accurate PPS insertion with a shorter fluoroscopy time.
Keywords: Accuracy; Minimally invasive; Oblique view; Pedicle screw fixation; Percutaneous.
Conflict of interest statement
No potential conflict of interest relevant to this article was reported.
Figures
References
-
- Foley KT, Gupta SK. Percutaneous pedicle screw fixation of the lumbar spine: preliminary clinical results. J Neurosurg. 2002;97(1 Suppl):7–12. - PubMed
-
- Ringel F, Stoffel M, Stuer C, Meyer B. Minimally invasive transmuscular pedicle screw fixation of the thoracic and lumbar spine. Neurosurgery. 2006;59(4 Suppl 2):ONS361–ONS366. - PubMed
-
- Harris EB, Massey P, Lawrence J, Rihn J, Vaccaro A, Anderson DG. Percutaneous techniques for minimally invasive posterior lumbar fusion. Neurosurg Focus. 2008;25:E12. - PubMed
-
- Nakashima H, Sato K, Ando T, Inoh H, Nakamura H. Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy-navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery. J Spinal Disord Tech. 2009;22:468–472. - PubMed
-
- Wood MJ, Mannion RJ. Improving accuracy and reducing radiation exposure in minimally invasive lumbar interbody fusion. J Neurosurg Spine. 2010;12:533–539. - PubMed
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials
