Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2016 Nov;32(11):2393-2400.
doi: 10.1016/j.arthro.2016.06.012. Epub 2016 Aug 25.

Changes in Patellar Height After Opening Wedge and Closing Wedge High Tibial Osteotomy: A Meta-analysis

Affiliations
Meta-Analysis

Changes in Patellar Height After Opening Wedge and Closing Wedge High Tibial Osteotomy: A Meta-analysis

Seong-Il Bin et al. Arthroscopy. 2016 Nov.

Abstract

Purpose: To test that patellar height decreases (patellar baja) after opening wedge high tibial osteotomy (HTO) and increases (patellar alta) after closing wedge HTO. In addition, this meta-analysis evaluated whether the method of measuring patellar height affected the change in patellar height after opening and closing HTO.

Methods: Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, all studies comparing pre- and postoperative patellar height using various indices, including the Insall-Salvati index (ISI), Blackburne-Peel index, and Caton Deschamps index, in patients who underwent opening or closing wedge HTO were included. The main outcome of this meta-analysis, mean change in patellar height from before to after surgery, was analyzed with a random effects model. Publication bias was evaluated using funnel plots and Egger's test.

Results: Twenty-three studies were included in the meta-analysis. Pooled data, including subgroups of the 3 measurement methods, showed that patellar height decreased 7% after opening wedge HTO (95% confidence interval [CI]: 0.05 to 0.10; P < .001), except when patellar height was assessed by ISI (95% CI: -0.02 to 0.06; P = .34), but that there was no change in patellar height after closing HTO (95% CI: -0.01 to 0.04; P = .29).

Conclusions: The patellar height decreased after opening wedge HTO, except when assessed by ISI. In contrast, patellar height was unchanged after closing wedge HTO, regardless of the measurement method.

Level of evidence: Level II, meta-analysis of Level I and II studies.