A randomized clinical trial comparing mandibular incisor proclination produced by fixed labial appliances and clear aligners
- PMID: 27571371
- PMCID: PMC8600838
- DOI: 10.2319/101415-686.1
A randomized clinical trial comparing mandibular incisor proclination produced by fixed labial appliances and clear aligners
Abstract
Objective: To compare the mandibular incisor proclination produced by fixed labial appliances and third generation clear aligners.
Materials and methods: Patients underwent a course of orthodontic treatment using either fixed labial appliances or clear aligners (Invisalign). Mandibular incisor proclination was measured by comparing pretreatment and near-end treatment lateral cephalograms. Eligibility criteria included adult patients with mild mandibular incisor crowding (<4 mm) and Class I skeletal bases (ANB, 1-4°). The main outcome was the cephalometric change in mandibular incisor inclination to the mandibular plane at the end of treatment. Eligible patients picking a sealed opaque envelope, which indicated their group allocation, was used to achieve randomization. Data was analyzed using a Welch two-sample t-test.
Results: Forty-four patients (mean age, 26.4 ± 7.7 years) were randomized in a 1:1 ratio to either the fixed labial appliance or the clear aligner group. Baseline characteristics were similar for both groups: Fixed appliance mean crowding was 2.1 ± 1.3 mm vs clear aligner mean crowding, 2.5 ± 1.3 mm; pretreatment mean mandibular incisor inclination for the fixed appliance group was 90.8 ± 5.4° vs 91.6 ± 6.4° for the clear aligner group. Fixed appliances produced 5.3 ± 4.3° of mandibular incisor proclination. Clear aligners proclined the mandibular incisors by 3.4 ± 3.2°. The difference between the two groups was not statistically significant (P > .05).
Conclusion: There was no difference in the amount of mandibular incisor proclination produced by clear aligners and fixed labial appliances in mild crowding cases.
Keywords: Clear aligners; Fixed appliances; Tooth movement.
Figures
References
-
- Jeremiah HG, Bister D, Newton JT. Social perceptions of adults wearing orthodontic appliances: a cross-sectional study. Eur J Orthod. 2011;33:476–482. - PubMed
-
- Miller KB, McGorray SP, Womack R, et al. A comparison of treatment impacts between Invisalign aligner and fixed appliance therapy during the first week of treatment. Am J Orthod Dentofacial Orthop. 2007;131:302, e301–e309. - PubMed
-
- Miethke RR, Brauner K. A Comparison of the periodontal health of patients during treatment with the Invisalign system and with fixed lingual appliances. J Orofac Orthop/Fortschritte der Kieferorthopadie. 2007;68:223–231. - PubMed
-
- Barbagallo LJ, Jones AS, Petocz P, Darendeliler MA. Physical properties of root cementum: part 10. Comparison of the effects of invisible removable thermoplastic appliances with light and heavy orthodontic forces on premolar cementum. A microcomputed-tomography study. Am J Orthod Dentofacial Orthop. 2008;133:218–227. - PubMed
-
- Hennessy J, Al-Awadhi EA. Clear aligners generations and orthodontic tooth movement. J Orthod. 2015 1465313315Y0000000004. [Epub ahead of print] - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical