Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2016 Nov:178:81-86.e2.
doi: 10.1016/j.jpeds.2016.08.004. Epub 2016 Aug 26.

Effect of Delayed Cord Clamping on Systemic Blood Flow: A Randomized Controlled Trial

Affiliations
Randomized Controlled Trial

Effect of Delayed Cord Clamping on Systemic Blood Flow: A Randomized Controlled Trial

Himanshu Popat et al. J Pediatr. 2016 Nov.

Abstract

Objective: To determine whether delayed cord clamping improves systemic blood flow compared with immediate cord clamping in very preterm infants in the first 24 hours.

Study design: Women delivering at <30 weeks' gestation at 5 tertiary centers were randomized to receive immediate cord clamping (<10 seconds) or delayed cord clamping (≥60 seconds). Echocardiography and cardiorespiratory data were collected at 3, 9, and 24 hours after birth. The primary outcome was mean lowest superior vena cava (SVC) flow.

Results: Of 266 infants enrolled, 133 were randomized to immediate cord clamping and 133 to delayed cord clamping. The 2 groups were similar at baseline, including mean gestation (immediate cord clamping 28 weeks vs delayed cord clamping 28 weeks) and birth weight (immediate cord clamping 1003 g vs delayed cord clamping 1044 g). There was no significant difference between groups in the primary outcome of mean lowest SVC flow (immediate cord clamping 71.4 mL/kg/min [SD 28.1] vs delayed cord clamping 70.2 mL/kg/min [SD 26.9]; P = .7). For secondary outcomes, hemoglobin increased by 0.9 g/dL at 6 hours in the group with delayed cord clamping (95% CI 3.9, 14.4; P = .0005, adjusted for baseline). The group with delayed cord clamping had lower right ventricular output (-21.9 mL/kg/min, 95% CI -39.0, -4.7; P = .01). Rates of treated hypotension, ductus arteriosus size and shunt direction, and treatment of the ductus arteriosus were similar.

Conclusions: Delayed cord clamping had no effect on systemic blood flow measured as mean lowest SVC flow in the first 24 hours in infants <30 weeks' gestation.

Trial registration: Australia New Zealand Clinical Trials Registry: ACTRN12610000633088.

Keywords: cardiac output; hemodynamics; premature infant.

PubMed Disclaimer

Similar articles

Cited by

Publication types