Rotating Scheimpflug Imaging Indices in Different Grades of Keratoconus
- PMID: 27579178
- PMCID: PMC4992767
- DOI: 10.1155/2016/6392472
Rotating Scheimpflug Imaging Indices in Different Grades of Keratoconus
Abstract
Purpose. To evaluate accuracy of various Keratoconus (KC) screening indices, in relation to Topographic Keratoconus (TKC) grading. Setting. Al Watany Eye Hospital, Cairo, Egypt. Methods. Data of 103 normal (group 1) and 73 KC eyes (group 2), imaged by Pentacam (branded as Allegro Oculyzer), were analysed. Group 2 was divided into 2a: 14 eyes (TKC = 1, early KC), 2b: 25 eyes (TKC = 1 to 2 or 2, moderate KC), and 2c: 34 eyes (TKC = 2 to 3 up to 4, severe KC). Participants were followed up for six years to confirm diagnosis. Area under the receiver operating characteristic curve (AUROC) was calculated for evaluated curvature, elevation, and pachymetry indices with various reference shapes at different diameters. Results. When comparing normal to KC eyes, ten indices had significantly higher AUROC. Only five of them had significantly higher AUROC in early KC compared to normal corneas: Pachymetry Progression Index- (PPI-) Maximum (Max), Ambrósio's Relational Thickness- (ART-) Max, PPI-Max minus PPI-Minimum (Min), central corneal thickness (CCT), and diagonal decentration of thinnest point from the apex (AUROC = 0.690, 0.690, 0.687, 0.683, and 0.674, resp.). Conclusion. Generally, ten pachymetry and elevation-based indices had significantly higher AUROC. Five indices had statistically significant high AUROC when comparing early KC to normal corneas.
Similar articles
-
Diagnostic accuracy of different keratoconus detection indices of pentacam in paediatric eyes.Eye (Lond). 2023 Apr;37(6):1130-1138. doi: 10.1038/s41433-022-02070-x. Epub 2022 May 3. Eye (Lond). 2023. PMID: 35505110 Free PMC article.
-
[Characteristics of corneal topography in parents of keratoconus patients].Zhonghua Yan Ke Za Zhi. 2020 Jun 11;56(6):456-464. doi: 10.3760/cma.j.cn112142-20191008-00200. Zhonghua Yan Ke Za Zhi. 2020. PMID: 32842328 Chinese.
-
Early, Forme Fruste keratoconus and normal thin cornea, evaluation of sensitive parameters by combined Placido Scheimpflug topography.Eur J Ophthalmol. 2024 Jan;34(1):59-70. doi: 10.1177/11206721231199506. Epub 2023 Sep 20. Eur J Ophthalmol. 2024. PMID: 37731321
-
New corneal assessment index from the relational thickness and other OCULUS values (CAIRO Index).Clin Ophthalmol. 2018 Aug 23;12:1527-1532. doi: 10.2147/OPTH.S171827. eCollection 2018. Clin Ophthalmol. 2018. PMID: 30197498 Free PMC article.
-
Pentacam HR Indices Variation in Normal Corneas with Different Corneal Thickness.J Ophthalmol. 2018 Nov 8;2018:9328120. doi: 10.1155/2018/9328120. eCollection 2018. J Ophthalmol. 2018. PMID: 30533219 Free PMC article.
Cited by
-
The utility of measures of anterior segment parameters of a Pentacam Scheimpflug tomographer in discriminating high myopic astigmatism from keratoconus.PLoS One. 2021 Dec 2;16(12):e0260648. doi: 10.1371/journal.pone.0260648. eCollection 2021. PLoS One. 2021. PMID: 34855828 Free PMC article.
-
Pentacam® Corneal Tomography for Screening of Refractive Surgery Candidates: A Review of the Literature, Part I.Med Hypothesis Discov Innov Ophthalmol. 2019 Fall;8(3):177-203. Med Hypothesis Discov Innov Ophthalmol. 2019. PMID: 31598520 Free PMC article. Review.
-
Evaluation of Choroidal Vascularity Index in Keratoconus Patients: Does Choroidal Vascularity Change in Keratoconus?J Curr Ophthalmol. 2023 Aug 11;35(1):36-41. doi: 10.4103/joco.joco_189_22. eCollection 2023 Jan-Mar. J Curr Ophthalmol. 2023. PMID: 37680286 Free PMC article.
-
Keratoconus Detection Based on a New Corneal Volumetric Analysis.Sci Rep. 2017 Nov 20;7(1):15837. doi: 10.1038/s41598-017-16145-3. Sci Rep. 2017. PMID: 29158547 Free PMC article.
-
Diagnosis of forme fruste keratoconus with scheimpflug photography in Ghanaian patients.BMC Ophthalmol. 2024 Jul 15;24(1):285. doi: 10.1186/s12886-024-03563-x. BMC Ophthalmol. 2024. PMID: 39009964 Free PMC article.
References
-
- Belin M. W., Litoff D., Strods S. J., Winn S. S., Smith R. S. The PAR technology corneal topography system. Refractive and Corneal Surgery. 1992;8(1):88–96. - PubMed
-
- Smolek M. K. What is keratoconus? In: Boxer Wachler B. S., editor. Modern Management of Keratoconus. 1st. New Delhi, India: Jaypee Brothers Medical Publishers; 2008. p. p. 3.
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous