. 2018 Feb;25(1):181-190.
doi: 10.1007/s12350-016-0610-4. Epub 2016 Aug 31.

Standardization of 99mTechnetium pyrophosphate imaging methodology to diagnose TTR cardiac amyloidosis

Affiliations

Standardization of 99mTechnetium pyrophosphate imaging methodology to diagnose TTR cardiac amyloidosis

Sabahat Bokhari et al. J Nucl Cardiol. 2018 Feb.

Erratum in

Abstract

Background: Technetium pyrophosphate (99mTc-PYP) imaging to diagnose transthyretin cardiac amyloidosis (ATTR-CA) has been increasingly utilized. The objective of this study is to provide a standardized 99mTc-PYP imaging protocol to diagnose ATTR-CA.

Methods: 104 scans from 45 subjects with biopsy-proven ATTR-CA or light-chain cardiac amyloidosis (AL) were assessed. Multiple scans were obtained using different counts (750 vs 2000 K), times to acquisition (1 vs 2 to 4 hours), processing matrix (256 vs 128), and 99mTc-PYP dose. Image quality and extracardiac activity was assessed. Quantitative methods using heart-to-contralateral ratios (H/CL) and a visual semiquantitative scale were used to diagnose ATTR-CA.19 The correlation between H/CL ratios and reproducibility of semiquantitative visual scores, acquired using various imaging parameters, were evaluated.

Results: All imaging parameters had good to excellent image quality. 750 vs 2000 K counts, 1 hour acquisition and 256 matrix, had lower extracardiac activity (P = .00018). 10 mCi of 99mTc-PYP v. higher doses showed excellent image quality and less extracardiac activity (P = .0015). Correlation of H/CL ratios was strong (r ≥ 0.92) and reproducibility of semiquantitative visual scores was high (Kappa = 95%).

Conclusion: An imaging protocol using 750 K counts, 10 mCi of 99mTc-PYP, and a 256 matrix was chosen as the standardized imaging protocol since it provided the shortest overall study time (1 vs 2 to 4 hours) and lowest radiation exposure (3 vs 8 to 10 mSv).

Keywords: 99mTc-PYP; ATTR-CA; amyloid; amyloidosis; non-invasive; standardized imaging protocol.

PubMed Disclaimer

Comment in

References

    1. Front Cardiovasc Med. 2015 May 08;2:23 - PubMed
    1. Arch Intern Med. 1987 Jun;147(6):1039-44 - PubMed
    1. Int J Cardiol. 1987 Mar;14 (3):365-9 - PubMed
    1. Aging health. 2013 Apr 1;9(2):229-235 - PubMed
    1. Am Heart J. 1982 Apr;103(4 Pt 1):468-73 - PubMed

Publication types

MeSH terms

Substances