Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Aug 18;9(8):1127-33.
doi: 10.18240/ijo.2016.08.07. eCollection 2016.

Correlation between visual function and refractive, topographic, pachymetric and aberrometric data in eyes with keratoconus

Affiliations

Correlation between visual function and refractive, topographic, pachymetric and aberrometric data in eyes with keratoconus

Neslihan Bayraktar Bilen et al. Int J Ophthalmol. .

Abstract

Aim: To analyze the relationship between two visual functions and refractive, topographic, pachymetric and aberrometric indicators in eyes with keratoconus.

Methods: Corrected distance visual acuity (CDVA), and letter contrast sensitivity (CS) were correlated with refraction, corneal topography, pachymetry, and total corneal wavefront data prospectively in 71 eyes with keratoconus. The topographic indices assessed were simulated keratometry for the flattest and steepest meridians (SimK1 and SimK2), posterior steeper K (Ks), elevation value in best-fit sphere (BFS) maps, squared eccentricity (Є(2)), aspheric asymmetric index (AAI), pachymetry, thickness progression index (TPI), the amount of pachymetric decentralization (APD), and GalileiTM-keratoconus indices.

Results: The mean CDVA (expressed as logMAR) were 0.25±0.21. The mean CS was 1.25±0.46. The spherical refraction correlated well with CDVA (r=-0.526, P<0.001). From topographic indices, SRI correlated with CS (r=-0.695), and IAI with CS (r=-0.672) (P<0.001 for all). Root mean square (RMS) was 4.3±1.81 µm, spherical aberration (SA) was -0.4±0.67 µm, vertical and horizontal coma were -2.1±1.47 and -0.4±0.72 µm. All wavefront data (except horizontal coma), AAI, Є(2) and maximum BFS correlated significantly with the visual function (P≤0.001 for all).

Conclusion: In this study, CS is more affected than CDVA as a visual function. The quantity and quality of vision is significantly correlated with well-known and new topographic indices. There is not a significant correlation between visual function and pachymetric parameters. The significantly correlated indices can be used in staging keratoconus and to follow the outcome of a treatment.

Keywords: contrast sensitivity; corneal aberration; keratoconus; topographic index; visual quality.

PubMed Disclaimer

References

    1. Krachmer JH, Feder RS, Belin MW. Keratoconus and related noninflammatory corneal thinning disorders. Surv Ophthalmol. 1984;28(4):293–322. - PubMed
    1. Rabinowitz YS. Keratoconus. Surv Ophthalmol. 1998;42(4):297–319. - PubMed
    1. Rio-Cristobal A, Martin R. Corneal assessment technologies: current status. Surv Ophthalmol. 2014;59(6):599–614. - PubMed
    1. Lee YW, Choi CY, Yoon GY. Comparison of dual rotating Scheimpflug-Placido, swept-source optical coherence tomography, and Placido-scanning-slit systems. J Cataract Refract Surg. 2015;41(5):1018–1029. - PubMed
    1. Karnowski K, Kaluzny BJ, Szkulmowski M, Gora M, Wojtkowski M. Corneal topography with high-speed swept source OCT in clinical examination. Biomed Opt Express. 2011;2(9):2709–2720. - PMC - PubMed

LinkOut - more resources