Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Published Erratum
. 2016 Nov:130:196-197.
doi: 10.1016/j.mimet.2016.08.011. Epub 2016 Sep 3.

Corrigendum to "sonicating multi-lumen sliced catheter tips after the roll-plate technique improves the detection of catheter colonization in adults" [J. Microbiol. Methods 122 (2016) 20-22]

Affiliations
Published Erratum

Corrigendum to "sonicating multi-lumen sliced catheter tips after the roll-plate technique improves the detection of catheter colonization in adults" [J. Microbiol. Methods 122 (2016) 20-22]

María Guembe et al. J Microbiol Methods. 2016 Nov.

Abstract

The Maki technique is the standard method for detecting catheter tip (CT) colonization. However, some "multi-lumen" catheters finish in a vaulted fornix and end at different distances from the CT. Therefore, we compared the traditional Maki technique with the sonication method using several cross-cut fragments of the CT. Our objective was to assess the yield of the Maki technique followed by sonication in the detection of adult CT colonization and catheter-related bloodstream infection (C-RBSI). For 3months, we prospectively performed CT cultures of polyurethane catheters from adult patients admitted to our institution. First, we performed CT culture using the Maki technique on blood agar plates and then sonicated small fragments of CTs in 5ml of BHI followed by culture of 100μl of the sonicate. We included a total of 252 CVCs, with overall colonization and C-RBSI rates of 14.3% (36/252) and 5.9% (15/252). Of the 36 colonized CVCs, 21 (58.3%) were detected both by Maki and sonication, 6 (16.7%) were detected only by Maki technique, and 9 (25.0%) only by sonication method. Among 15 episodes with concomitant bacteremia, both techniques were positive and concordant in 11 cases (73.3%) and in 4 cases (26.7%) sonication was the only positive technique. Our study shows that both techniques are complementary. We recommend sonicating fragments of the CT from patients with bacteremia of unknown origin and a negative CT culture by the Maki technique.

PubMed Disclaimer

Erratum for

Publication types

LinkOut - more resources