. 2016 Aug 29:31:e2016019.
doi: 10.5620/eht.e2016019. eCollection 2016.

Humidifier disinfectant lung injury, how do we approach the issues?

Affiliations

Humidifier disinfectant lung injury, how do we approach the issues?

Jihyun Emma Choi et al. Environ Health Toxicol. .

Abstract

A large portion of the Korean population has been exposed to toxic humidifier disinfectants (HDs), and considering that the majority of the victims are infants, the magnitude of the damage is expected to be considerably larger than what has currently been revealed. The current victims are voicing problems caused by various diseases, including but not limited to lung, upper respiratory tract, cardiovascular, kidney, musculoskeletal, eye, and skin diseases, etc. However, there has been difficulty in gaining validation for these health problems and identifying causal relationships due to lack of evidence proving that toxic HD is the specific causes of extrapulmonary diseases such as allergic rhinitis. Furthermore, the victims and bereaved families of the HD case have not received any support for psychological distress such as post-traumatic stress disorder, depression, feelings of injustice, and anger caused by the trauma. In addition, because the underlying mechanisms of the toxic materials within the HDs such as polyhexamethylene guanidine phosphate, poly(oxyalkylene guanidine) hydrochloride, chloromethylisothiazolinone/methylisothiazolinone have yet to be determined, the demand for information regarding the HD issue is growing. The victims of the HD cases require support that goes beyond financial aid for medical costs and living expenses. There is a desperate need for government-led integrated support centers that provide individualized support through health screenings; in other words, we need an integrated facility that provides the appropriate social support to allow the victims to recover their physical and mental health, so as to well prepare them to return to a normal life. The implementation of such a plan requires not only the close cooperation between those departments already directly involved such as the Ministry of Environment and the Ministry of Health and Welfare, but also active support on a national scale from pan-governmental consultative bodies.

Keywords: Disaster; Humidifier disinfectant; Lung injury; National center; Psychiatric trauma.

PubMed Disclaimer

Conflict of interest statement

The author has no conflicts of interest associated with material presented in this paper.

Figures

Figure 1.
Figure 1.
Individualized mental and social support system.
Figure 2.
Figure 2.
Integrated support center for humidifier disinfectant victims.

References

    1. Cheon CK, Jin HS, Kang EK, Kim HB, Kim BJ, Yu JH, et al. Epidemic acute interstitial pneumonia in children occurred during the early 2006s. Korean J Pediatr. 2008;51(4):383–390. (Korean)
    1. Lee E, Seo JH, Kim HY, Yu J, Jhang WK, Park SJ, et al. Toxic inhalational injury-associated interstitial lung disease in children. J Korean Med Sci. 2013;28(6):915–923. - PMC - PubMed
    1. Yang HJ, Kim HJ, Yu J, Lee E, Jung YH, Kim HY, et al. Inhalation toxicity of humidifier disinfectants as a risk factor of children’s interstitial lung disease in Korea: a case-control study. PLoS One. 2013;8(6):e2016019 - PMC - PubMed
    1. Kim KW, Ahn K, Yang HJ, Lee S, Park JD, Kim WK, et al. Humidifier disinfectant-associated children’s interstitial lung disease. Am J Respir Crit Care Med. 2014;189(1):48–56. - PubMed
    1. Hong SB, Kim HJ, Huh JW, Do KH, Jang SJ, Song JS, et al. A cluster of lung injury associated with home humidifier use: clinical, radiological and pathological description of a new syndrome. Thorax. 2014;69(8):694–702. - PubMed