Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2016 Nov 1;118(9):1368-1373.
doi: 10.1016/j.amjcard.2016.07.070. Epub 2016 Aug 13.

Meta-Analysis of the Usefulness of Change in QRS Width to Predict Response to Cardiac Resynchronization Therapy

Affiliations
Meta-Analysis

Meta-Analysis of the Usefulness of Change in QRS Width to Predict Response to Cardiac Resynchronization Therapy

Panagiotis Korantzopoulos et al. Am J Cardiol. .

Abstract

The existing data regarding the role of QRS duration (QRSd) change on cardiac resynchronization therapy (CRT) response show some inconsistent results. We conducted a meta-analysis of data obtained from observational studies to examine the impact of QRS change after CRT device implantation on the clinical and/or echocardiographic response. We searched the PubMed and EMBASE databases for relevant studies published before January 2016. Twenty-seven studies were retrieved for detailed evaluation of which 12 studies with a total population of 1,545 patients met our eligibility criteria. The analysis demonstrated that QRSd narrowing was a positive predictor of response to CRT (mean difference [MD] = -19.24 ms, 95% CI = -24.00 to -14.48 ms, p <0.00001). This effect was consistent in the studies using clinical criteria (MD = -19.91 ms, 95% CI = -27.20 to -12.62 ms, p <0.00001) and in those that used echocardiographic criteria (MD = -19.51 ms, 95% CI = -25.78 to -13.25 ms, p <0.00001). The heterogeneity test showed moderate differences among the individual studies (I2 = 42%). Subgroup analysis showed that QRSd change was more pronounced in studies having a follow-up ≤6 months. We did not find significant differences in studies measuring postimplantation QRSd after a certain follow-up period compared with studies measuring QRSd immediately after CRT device implantation. Further studies should clarify the exact timing of QRSd assessments during follow-up. In conclusion, QRSd shortening after CRT device implantation is associated with a favorable clinical and echocardiographic response.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources