Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2017 Jan-Feb:83:42-54.
doi: 10.1016/j.vascn.2016.09.004. Epub 2016 Sep 17.

Comprehensive in vitro cardiac safety assessment using human stem cell technology: Overview of CSAHi HEART initiative

Affiliations
Review

Comprehensive in vitro cardiac safety assessment using human stem cell technology: Overview of CSAHi HEART initiative

Kiyoshi Takasuna et al. J Pharmacol Toxicol Methods. 2017 Jan-Feb.

Abstract

Recent increasing evidence suggests that the currently-used platforms in vitro IKr and APD, and/or in vivo QT assays are not fully predictive for TdP, and do not address potential arrhythmia (VT and/or VF) induced by diverse mechanisms of action. In addition, other cardiac safety liabilities such as functional dysfunction of excitation-contraction coupling (contractility) and structural damage (morphological damage to cardiomyocytes) are also major causes of drug attrition, but current in vitro assays do not cover all these liabilities. We organized the Consortium for Safety Assessment using Human iPS cells (CSAHi; http://csahi.org/en/), based on the Japan Pharmaceutical Manufacturers Association (JPMA), to verify the application of human iPS/ES cell-derived cardiomyocytes in drug safety evaluation. The main goal of the CSAHi HEART team has been to propose comprehensive screening strategies to predict a diverse range of cardiotoxicities by using recently introduced platforms (multi-electrode array (MEA), patch clamp, cellular impedance, motion field imaging [MFI], and Ca transient systems) while identifying the strengths and weaknesses of each. Our study shows that hiPS-CMs used in these platforms have pharmacological responses more relevant to humans in comparison with existent hERG, APD or Langendorff (MAPD/contraction) assays, and not only MEA but also other methods such as impedance, MFI, and Ca transient systems would offer paradigm changes of platforms for predicting drug-induced QT risk and/or arrhythmia or contractile dysfunctions. Furthermore, we propose a potential multi-parametric platform in which field potential (MEA)-Ca transient-contraction (MFI) could be evaluated simultaneously as an ideal novel platform for predicting a diversity of cardiac toxicities, namely whole effects on the excitation-contraction cascade.

Keywords: CSAHi; Ca transient; Cardiac liability; Human induced pluripotent stem cell-derived cardiomyocytes (hiPS-CMs); Impedance; Motion field imaging; Multi-electrode arrays; Multi-parametric; Simulation; Stem cell.

PubMed Disclaimer

MeSH terms

Substances

LinkOut - more resources