Clinical Trial
. 2016 Nov 10;26(6):585-590.
doi: 10.5301/hipint.5000388. Epub 2016 Sep 20.

Major acetabular defects treated with the Burch-Schneider antiprotrusion cage and impaction bone allograft in a large series: a 5- to 7- year follow-up study

Affiliations
Clinical Trial

Major acetabular defects treated with the Burch-Schneider antiprotrusion cage and impaction bone allograft in a large series: a 5- to 7- year follow-up study

Axel Marx et al. Hip Int. .

Abstract

Introduction: Major bone defects are the greatest challenge in hip revision arthroplasty.

Methods: In a prospective, consecutive nonrandomised study we followed up 74 patients with Type III (AAOS) acetabular bone defects who underwent revision hip arthroplasty with bone grafting and implantation of a Burch-Schneider anti-protrusion cage (APC). The patients were examined pre- and postoperatively according to a standardised clinical and radiological protocol. No patient was lost to follow-up.

Results: 9 patients died before follow-up. In 9 other patients the APC was revised within the follow-up period. In 4 of these patients the revision was necessary because of aseptic loosening. In the remaining 5 cases joint infection, recurrent dislocation and 1 trauma were the reasons for revision. 56 patients were included in the statistical analysis. In the follow-up group the mean Harris Hip Score increased from 39.9 preoperatively to 73.2. 85% of the patients assessed their operation result as good or excellent.

Conclusions: In a large consecutive series the Burch-Schneider anti-protrusion cage proved to be a valuable option in the treatment of major acetabular bone defects in hip revision surgery.