Glove perforation during plastic surgery
- PMID: 2765743
- DOI: 10.1016/0007-1226(89)90019-2
Glove perforation during plastic surgery
Abstract
Intraoperative perforation of surgical gloves is common. Nine hundred and forty surgical gloves were tested after 100 consecutive plastic surgical operations, each involving a surgeon, a variable number of assistants and a scrub nurse. In the first 52 operations, single gloves were used and 21.5% of the staff were found to have a perforated glove. In the second 48 operations, double gloves were used by all members of the surgical team and the number with perforations (of both inner and outer gloves) was reduced to 9%. Most perforations occurred on the dorsum of the hand and fingers and on the thumb tip, especially in the non-dominant hand. The risk of acquiring AIDS due to glove perforation is low but the consequences of such an event could be lethal.
Similar articles
-
Rate of Glove Perforation in Open Abdominal Surgery and the Associated Risk Factors.Surg Infect (Larchmt). 2019 May/Jun;20(4):286-291. doi: 10.1089/sur.2018.229. Epub 2019 Feb 8. Surg Infect (Larchmt). 2019. PMID: 30735109
-
Frequency of glove perforations and subsequent blood contact in association with selected obstetric surgical procedures.Am J Obstet Gynecol. 1993 May;168(5):1354-7. doi: 10.1016/s0002-9378(11)90764-9. Am J Obstet Gynecol. 1993. PMID: 8498411
-
[Perforation of surgical gloves in gynecologic operations and abdominal Cesarean section].Geburtshilfe Frauenheilkd. 1992 Feb;52(2):109-12. doi: 10.1055/s-2007-1022963. Geburtshilfe Frauenheilkd. 1992. PMID: 1533198 German.
-
[Surgical gloves--how well do the protect against infections?].Gesundheitswesen. 1999 Aug-Sep;61(8-9):398-403. Gesundheitswesen. 1999. PMID: 10535220 Review. German.
-
[What is the appropriate time-interval for changing gloves during surgical procedures].Zentralbl Chir. 2010 Feb;135(1):25-7. doi: 10.1055/s-0029-1224684. Epub 2010 Jan 27. Zentralbl Chir. 2010. PMID: 20108181 Review. German.
Cited by
-
Occult glove perforation during ophthalmic surgery.Trans Am Ophthalmol Soc. 1992;90:71-91; discussion 92-5. Trans Am Ophthalmol Soc. 1992. PMID: 1494836 Free PMC article.
-
Subjective effects of double gloves on surgical performance.Ann R Coll Surg Engl. 1996 Jan;78(1):20-2. Ann R Coll Surg Engl. 1996. PMID: 8659967 Free PMC article. Clinical Trial.
-
Double gloving to reduce surgical cross-infection.Cochrane Database Syst Rev. 2006 Jul 19;2006(3):CD003087. doi: 10.1002/14651858.CD003087.pub2. Cochrane Database Syst Rev. 2006. PMID: 16855997 Free PMC article.
-
Glove Puncture During Liposuction: A Report of Two Cases.J Cutan Aesthet Surg. 2016 Jan-Mar;9(1):48-50. doi: 10.4103/0974-2077.178560. J Cutan Aesthet Surg. 2016. PMID: 27081254 Free PMC article. No abstract available.
-
High rates of perforation are found in endovaginal ultrasound probe covers before and after oocyte retrieval for in vitro fertilization-embryo transfer.J Assist Reprod Genet. 1995 Oct;12(9):606-9. doi: 10.1007/BF02212583. J Assist Reprod Genet. 1995. PMID: 8580658
MeSH terms
LinkOut - more resources
Full Text Sources