The effect of six degree of freedom loading sequence on the in-vitro compressive properties of human lumbar spine segments
- PMID: 27663622
- DOI: 10.1016/j.jbiomech.2016.09.009
The effect of six degree of freedom loading sequence on the in-vitro compressive properties of human lumbar spine segments
Abstract
The complex, direction-dependent, poro-viscoelastic properties of the intervertebral disc (disc) suggest that investigations of the six degree of freedom (6DOF) behaviour may be susceptible to inter-test variation in mechanical response if the disc does not return to initial conditions between loading directions. No studies have quantified the effects of sequential multi-directional loading on the consistency of the compressive response of the disc throughout a 6DOF testing protocol. Therefore, the objective of this study was to determine the effect of 6DOF loading on the compressive properties (stiffness and phase angle) of human discs, as evaluated by a reference compression test performed after each single DOF test. Fourteen intact human functional spinal units (FSU) were tested in each of ±6DOFs (shear directions followed by bending and compression) across four orders of magnitude loading frequencies (0.001-1Hz), followed by reference compression tests while subjected to physiological preload, hydration, and body temperature conditions in a hexapod robot. Repeated measures ANOVA revealed significant within-subjects effects between the reference compression tests for modulus (p<0.001), stiffness (p<0.001), and phase angle (p=0.008). Significant post-hoc pairwise comparisons were initially seen between the control and other reference compression tests for stiffness and modulus after the shear DOFs, however, no significant differences were present after the final reference compression test compared to control. More pronounced effects were seen for stiffness in comparison to modulus and phase angle. These effects may be due to three potentials factors, which include the sequence of testing, the cohort of degenerative specimens, and/or cumulative creep due to the constant application of a follower load. While the sequence of test directions was chosen to minimise the biphasic effect, there may be other sequences, which could result in minimal changes in compressive properties.
Keywords: Biomechanics; Compression; Intervertebral disc; Load history; Mechanical properties; Six degree of freedom.
Copyright © 2016 Elsevier Ltd. All rights reserved.
Similar articles
-
Intervertebral disc degeneration alters lumbar spine segmental stiffness in all modes of loading under a compressive follower load.Spine J. 2013 Sep;13(9):1134-47. doi: 10.1016/j.spinee.2013.02.010. Epub 2013 Mar 15. Spine J. 2013. PMID: 23507531
-
Effect of potting technique on the measurement of six degree-of-freedom viscoelastic properties of human lumbar spine segments.J Biomech Eng. 2015 May;137(5):054501. doi: 10.1115/1.4029698. Epub 2015 Feb 20. J Biomech Eng. 2015. PMID: 25646970
-
Effect of degeneration on the six degree of freedom mechanical properties of human lumbar spine segments.J Orthop Res. 2016 Aug;34(8):1399-409. doi: 10.1002/jor.23334. Epub 2016 Jun 28. J Orthop Res. 2016. PMID: 27291789
-
Biomechanics of the lumbar spine.Ann Med. 1989 Oct;21(5):347-51. doi: 10.3109/07853898909149219. Ann Med. 1989. PMID: 2532524 Review.
-
Mechanobiology of the intervertebral disc.Biochem Soc Trans. 2002 Nov;30(Pt 6):853-8. doi: 10.1042/bst0300853. Biochem Soc Trans. 2002. PMID: 12440932 Review.
Cited by
-
Can axial loading restore in vivo disc geometry, opening pressure, and T2 relaxation time?JOR Spine. 2024 Apr 25;7(2):e1322. doi: 10.1002/jsp2.1322. eCollection 2024 Jun. JOR Spine. 2024. PMID: 38666074 Free PMC article.
-
A novel spine tester TO GO.JOR Spine. 2024 Oct 27;7(4):e70002. doi: 10.1002/jsp2.70002. eCollection 2024 Dec. JOR Spine. 2024. PMID: 39469185 Free PMC article.
-
Composite biomaterial repair strategy to restore biomechanical function and reduce herniation risk in an ex vivo large animal model of intervertebral disc herniation with varying injury severity.PLoS One. 2019 May 28;14(5):e0217357. doi: 10.1371/journal.pone.0217357. eCollection 2019. PLoS One. 2019. PMID: 31136604 Free PMC article.
-
The role of biomechanical factors in models of intervertebral disc degeneration across multiple length scales.APL Bioeng. 2023 May 8;7(2):021501. doi: 10.1063/5.0137698. eCollection 2023 Jun. APL Bioeng. 2023. PMID: 37180733 Free PMC article. Review.
-
IL-1Ra deficiency accelerates intervertebral disc degeneration in C57BL6J mice.JOR Spine. 2022 Apr 23;5(2):e1201. doi: 10.1002/jsp2.1201. eCollection 2022 Jun. JOR Spine. 2022. PMID: 35783913 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources