Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Sep 7;51(9):661-665.
doi: 10.3760/cma.j.issn.1673-0860.2016.09.005.

[A comparison of pH<4 and pH<5 as thresholds for 24-hour pH monitoring in the diagnosis of laryngopharyngeal reflux]

[Article in Chinese]
Affiliations

[A comparison of pH<4 and pH<5 as thresholds for 24-hour pH monitoring in the diagnosis of laryngopharyngeal reflux]

[Article in Chinese]
J S Wang et al. Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. .

Abstract

Objective: To evaluate the consistency between 24-hour pH monitoring, reflux symptom index(RSI) and reflux finding score(RFS) when using pH<4 or pH<5 as threshold for 24-hour pH monitoring in the diagnosis of laryngopharyngeal reflux. Methods: Patients who presented with suspicious laryngopharyngeal reflux between February 2014 and December 2015 were included in this study. pH<4 and pH<5 reflux episodes, RSI and RFS were collected. The consistency between 24-hour pH monitoring and scale results were analyzed when pH<4 or pH<5 as threshold respectively. The sensitivity and specificity of 24-hour pH monitoring were calculated separately. Results: Median number(M[P25, P75, P95]) of reflux events were 0 [0, 3.0, 5.5] when using pH<4 as pathological threshold and 0 [0, 4.0, and 8.5] using pH<5 as pathological threshold. Laryngopharyngeal reflux was determined in 34.5% patients depending on 24-hour pH monitoring when pH<4 was used as threshold, chi-square revealed medium consistency (κ=0.483) between pH monitoring and scale result. If pH<5 was used as threshold, 41.8% patients were detected with laryngopharyngeal reflux, and the consistency of pH monitoring and scale result was medium(κ=0.540). With RSI and RFS for reference, the sensitivity and specificity of 24-hour pH monitoring were 54.7% and 93.4% respectively when pH<4 was used as threshold. If pH<5 was used as threshold, the sensitivity and specificity of 24-hour pH monitoring were 65.6% and 91.3% respectively. Conclusions: Compared with pH<4 as pathological threshold, the consistency of pH monitoring and scale results was a little better using pH<5 as pathological threshold.

PubMed Disclaimer