Nonmodular Tapered Fluted Titanium Stems Osseointegrate Reliably at Short Term in Revision THAs
- PMID: 27672012
- PMCID: PMC5174054
- DOI: 10.1007/s11999-016-5091-x
Nonmodular Tapered Fluted Titanium Stems Osseointegrate Reliably at Short Term in Revision THAs
Abstract
Background: The ideal femoral component for revision THA is undecided. Cylindrical nonmodular stems have been associated with stress shielding, whereas junctional fractures have been reported with tapered fluted modular titanium stems. We have used a tapered fluted nonmodular titanium femoral component (Wagner Self-locking [SL] femoral stem) to mitigate this risk. This component has been used extensively in Europe by its designer surgeons, but to our knowledge, it has not been studied in North America. Added to this, the design of the component has changed since early reports.
Questions/purposes: We asked: (1) Does the Wagner SL stem have low rates of rerevision and other complications at a minimum 2 years after surgery? (2) Is the Wagner SL stem associated with high levels of patient function and pain relief at a minimum 2 years after surgery? (3) Does the Wagner SL stem have low rates of subsidence at a minimum 2 years after surgery? (4) Is the Wagner SL stem associated with proximal femoral bone remodeling at a minimum 2 years after surgery?
Method: Between May 2011 and December 2012, we performed 198 femoral revisions, of which 104 (53%) were performed using the Wagner SL femoral stem; during that period, our institution gradually shifted toward increasing use of these stems for all but the most severe revisions, in which modular fluted stems and proximal femoral replacements still are used on an occasional basis. Median followup in this retrospective study was 32 months (range, 24-46 months), and one patient was lost to followup before the 2-year minimum. The femoral deformities in this series were Paprosky Type I (10 hips), Paprosky Type II (26), Paprosky Type IIIA (52), Paprosky Type IIIB (nine), and Paprosky Type IV (two). Functional assessment was performed using the Oxford Hip Score (OHS), WOMAC, SF-12, and the University of California Los Angeles (UCLA) activity score. All complications and cases of revision were documented. All patients had radiographs performed within 1 year of the latest followup. These were assessed by two surgeons for signs of proximal femoral bone remodeling and subsidence.
Results: Complete preoperative scores were available for 98 patients (98 of 104; 94%). The mean OHS preoperatively and at final followup were 39 (SD, 15) and 87 (SD, 19), respectively (p < 0.001; mean difference, 48; 95% CI, 43-53). Average WOMAC scores were 44 (SD, 15) and 87 (SD, 20), respectively (p < 0.001; mean difference, 43; 95% CI, 38-48). At final followup, signs of restoration of proximal femoral bone stock was noted in 45 of 103 hips (44%). Six (six of 104; 6%) patients had subsidence of 10 mm to 15 mm. In the remainder (98 of 104; 94%), the mean subsidence was 2 mm (range, 0-9 mm). One revision was performed for loosening associated with infection.
Conclusions: The Wagner SL stem is a viable option for patients with Paprosky Types II and III defects undergoing revision THA. This component provides high levels of patient function with low revision rates and low rates of subsidence during the early postoperative phase. They provide a viable alternative to modular components for treatment of Types II and III defects without the risk of junctional fractures. They can be used for very selected Type IV defects, however this extent of bone loss is most easily addressed with other techniques such as a proximal femoral replacement.
Level of evidence: Level IV, therapeutic study.
Comment in
-
CORR Insights®: Nonmodular Tapered Fluted Titanium Stems Osseointegrate Reliably at Short Term in Revision THAs.Clin Orthop Relat Res. 2017 Jan;475(1):193-195. doi: 10.1007/s11999-016-5144-1. Epub 2016 Oct 31. Clin Orthop Relat Res. 2017. PMID: 27798790 Free PMC article. No abstract available.
Similar articles
-
Long-term results of revision total hip arthroplasties using cementless stems and allografts for paprosky type IIIB and IV femoral defects short title: Revision hip arthroplasty in type IIIB and IV femoral defects.Int Orthop. 2025 Jan;49(1):109-116. doi: 10.1007/s00264-024-06367-2. Epub 2024 Nov 18. Int Orthop. 2025. PMID: 39551896
-
High Survivorship With Cementless Stems and Cortical Strut Allografts for Large Femoral Bone Defects in Revision THA.Clin Orthop Relat Res. 2015 Sep;473(9):2990-3000. doi: 10.1007/s11999-015-4358-y. Epub 2015 May 27. Clin Orthop Relat Res. 2015. PMID: 26013152 Free PMC article.
-
Is There a Benefit to Modularity in 'Simpler' Femoral Revisions?Clin Orthop Relat Res. 2016 Feb;474(2):415-20. doi: 10.1007/s11999-015-4474-8. Clin Orthop Relat Res. 2016. PMID: 26245164 Free PMC article.
-
Non-modular tapered fluted titanium stems in hip revision surgery: gaining attention.Bone Joint J. 2014 Nov;96-B(11 Supple A):56-9. doi: 10.1302/0301-620X.96B11.34302. Bone Joint J. 2014. PMID: 25381409 Review.
-
Tapered, fluted titanium stems in revision total hip arthroplasty: role and results in contemporary practice.Instr Course Lect. 2015;64:359-66. Instr Course Lect. 2015. PMID: 25745920 Review.
Cited by
-
Periprosthetic Fracture After Cementless Revision Total Hip Arthroplasty with a Tapered, Fluted Monobloc Stem: A Retrospective Long-Term Analysis of 121 Cases.J Clin Med. 2025 Apr 1;14(7):2409. doi: 10.3390/jcm14072409. J Clin Med. 2025. PMID: 40217859 Free PMC article.
-
Cementless total hip arthroplasty for failed treatment of subtrochanteric fracture.BMC Musculoskelet Disord. 2021 Apr 24;22(1):384. doi: 10.1186/s12891-021-04268-8. BMC Musculoskelet Disord. 2021. PMID: 33894763 Free PMC article.
-
Subsidence of monoblock and modular titanium fluted tapered stems in revision hip arthroplasty: A retrospective multicentre comparison study.J Clin Orthop Trauma. 2022 Sep 13;34:102021. doi: 10.1016/j.jcot.2022.102021. eCollection 2022 Nov. J Clin Orthop Trauma. 2022. PMID: 36147379 Free PMC article.
-
Differences between proximal bone remodeling in femoral revisions for aseptic loosening and periprosthetic fractures using the Wagner SL stem.BMC Musculoskelet Disord. 2021 Feb 17;22(1):201. doi: 10.1186/s12891-021-04062-6. BMC Musculoskelet Disord. 2021. PMID: 33596872 Free PMC article.
-
Long-term outcomes of cementless femoral stem revision with the Wagner cone prosthesis.J Orthop Surg Res. 2021 Jun 11;16(1):375. doi: 10.1186/s13018-021-02457-8. J Orthop Surg Res. 2021. PMID: 34116695 Free PMC article.
References
-
- Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988;15:1833–1840. - PubMed
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials