Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1989 Sep;14(3):660-5.
doi: 10.1016/0735-1097(89)90107-1.

Myocardial perfusion imaging by contrast echocardiography with use of intracoronary sonicated albumin in humans

Affiliations
Free article

Myocardial perfusion imaging by contrast echocardiography with use of intracoronary sonicated albumin in humans

S A Reisner et al. J Am Coll Cardiol. 1989 Sep.
Free article

Abstract

Sonicated albumin has been proposed as a near ideal echocardiographic contrast agent with little myocardial toxicity or hemodynamic effect. Its use has not yet been reported in humans, partly because of difficulties in preparation. With use of the newly modified sonication method, 10 ml of 5% albumin was sonicated for 75 s with a 5.0 ml slow infusion of air. This resulted in microbubbles with a mean diameter (+/- SD) of 5 +/- microns). Fourteen patients undergoing routine coronary angiography were studied. One patient had normal coronary arteries; the other 13 had significant coronary artery disease. In a subgroup of nine patients, sonicated albumin and sonicated diatrizoate meglumine sodium (microbubble diameter 9 +/- 3 microns) were injected several minutes apart, using the same technique. Videodensity-time curves were obtained from a region of interest in the myocardium. Corrected peak contrast intensity (baseline contrast intensity subtracted from peak contrast intensity, gray scale U/pixel) for sonicated albumin and for sonicated diatrizoate meglumine sodium was 51 +/- 26 and 52 +/- 19, respectively (p = 0.89). Washout half-time (T1/2) for the two agents was 5.5 +/- 4.5 and 16.0 +/- 12.2 s, respectively (p = 0.01). One patient with unstable angina experienced transient chest pain after repeated albumin injections. No electrocardiographic changes, blood pressure changes or wall motion abnormalities were observed. Administered by intracoronary injection, sonicated 5% albumin is a safe and effective echocardiographic contrast agent for myocardial perfusion imaging, yielding excellent myocardial contrast with physiologic washout time.

PubMed Disclaimer

Publication types

LinkOut - more resources