Computerized artifact detection for ventilatory inductance plethysmographic apnea monitors
- PMID: 2769315
- DOI: 10.1007/BF01627449
Computerized artifact detection for ventilatory inductance plethysmographic apnea monitors
Abstract
Ventilatory inductive plethysmography allows noninvasive monitoring of patient ventilation. Patient movements unrelated to breathing introduce severe errors in ventilator inductive plethysmographic measurements and restrict its usefulness. The purpose of this research was to develop and test a microprocessor-based real-time digital signal processor that uses an adaptive filter to detect patient movements unrelated to breathing. The adaptive filter processor was tested for retrospective identification of artifacts in 20 male volunteers who performed the following specific movements between epochs of quiet, supine breathing: raising arms and legs (slowly, quickly, once, and several times), sitting up, breathing deeply and rapidly, and rolling from a supine to a lateral decubitus position. Flow was simultaneously measured directly with a pneumotachography attached to a mouthpiece. A multilinear regression was used to continuously calculate the calibration constants that relate the pneumotachographic and ventilatory inductive plethysmographic signals. Ventilatory inductive plethysmographic data were then processed, and results scored. There were a total of 166 movements. The calibration coefficients changed dramatically in 146 (88%) of the 166 movements. These movements would have significant errors on ventilatory inductive plethysmographic flow calculation. The changes lasted for the duration of the movements and returned to baseline within two to three breaths. The changes in the coefficients were five or more times larger than the variability around baseline during quiet, supine breathing. All of the total body movements and changes in breathing patterns were detected accurately. The filter detected 46 of 53 upper body movements, 34 of 36 lower body movements, 38 of 38 total body movements, and 19 of 19 breathing pattern changes where the calibration changed.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Calibration of respiratory inductive plethysmography during quiet and active sleep in lambs.J Dev Physiol. 1989 Dec;12(6):347-52. J Dev Physiol. 1989. PMID: 2640229
-
Comparison of respiratory inductive plethysmography and thoracic impedance for apnea monitoring.J Pediatr. 1987 Sep;111(3):377-83. doi: 10.1016/s0022-3476(87)80457-2. J Pediatr. 1987. PMID: 3625404
-
Pressure sensor plethysmography: a method for assessment of respiratory motion in children.Eur Respir J. 1995 Jan;8(1):167-71. doi: 10.1183/09031936.95.08010167. Eur Respir J. 1995. PMID: 7744184
-
Validation of respiratory inductive plethysmography in patients with pulmonary disease.Chest. 1983 Apr;83(4):615-20. doi: 10.1378/chest.83.4.615. Chest. 1983. PMID: 6831949
-
Assessment of an alternative calibration technique to record breathing pattern and its variability with respiratory inductive plethysmography.J Clin Monit Comput. 2017 Aug;31(4):755-764. doi: 10.1007/s10877-016-9894-9. Epub 2016 Jun 11. J Clin Monit Comput. 2017. PMID: 27289525
Cited by
-
Automated anesthesia artifact analysis: can machines be trained to take out the garbage?J Clin Monit Comput. 2021 Apr;35(2):225-227. doi: 10.1007/s10877-020-00589-6. Epub 2020 Sep 12. J Clin Monit Comput. 2021. PMID: 32920701 No abstract available.
-
Rib cage and abdominal piezoelectric film belts to measure ventilatory airflow.J Clin Monit. 1990 Oct;6(4):276-83. doi: 10.1007/BF02842487. J Clin Monit. 1990. PMID: 2230857
-
Tissue artifact removal from respiratory signals based on empirical mode decomposition.Ann Biomed Eng. 2013 May;41(5):1003-15. doi: 10.1007/s10439-013-0742-5. Epub 2013 Jan 17. Ann Biomed Eng. 2013. PMID: 23325303 Free PMC article.
-
Evaluation of a parallel implementation of the learning portion of the backward error propagation neural network: experiments in artifact identification.Proc Annu Symp Comput Appl Med Care. 1991:290-4. Proc Annu Symp Comput Appl Med Care. 1991. PMID: 1807607 Free PMC article.