. 2017 Feb;25(2):501-516.
doi: 10.1007/s00167-016-4326-4. Epub 2016 Oct 1.

The efficacy of post-operative devices following knee arthroscopic surgery: a systematic review

Affiliations

The efficacy of post-operative devices following knee arthroscopic surgery: a systematic review

Corey T Gatewood et al. Knee Surg Sports Traumatol Arthrosc. 2017 Feb.

Abstract

Purpose: There is a wide array of device modalities available for post-operative treatment following arthroscopic knee surgery; however, it remains unclear which types and duration of modality are the most effective. This systematic review aimed to investigate the efficacy of device modalities used following arthroscopic knee surgery.

Methods: A systematic search of the literature was performed on: PubMed; Scopus; MEDLINE; EMBASE; PEDro; SportDiscus; and CINAHL databases (1995-2015) for clinical trials using device modalities following arthroscopic knee surgery: cryotherapy, continuous passive motion (CPM), neuromuscular electrical stimulation (NMES), surface electromyographic (sEMG) biofeedback and shockwave therapy (ESWT). Only level 1 and 2 studies were included and the methodological quality of studies was evaluated using Physiotherapy Evidence Database (PEDro) scores. Outcome measures included: muscle strength, range of motion, swelling, blood loss, pain relief, narcotic use, knee function evaluation and scores, patient satisfaction and length of hospital stay.

Results: Twenty-five studies were included in this systematic review, nineteen of which found a significant difference in outcomes. For alleviating pain and decreasing narcotic consumption following arthroscopic knee surgery, cryocompression devices are more effective than traditional icing alone, though not more than compression alone. CPM does not affect post-operative outcomes. sEMG biofeedback and NMES improve quadriceps strength and overall knee functional outcomes following knee surgery. There is limited evidence regarding the effects of ESWT.

Conclusion: Cryotherapy, NMES and sEMG are recommended for inclusion into rehabilitation protocols following arthroscopic knee surgery to assist with pain relief, recovery of muscle strength and knee function, which are all essential to accelerate recovery. CPM is not warranted in post-operative protocols following arthroscopic knee surgery because of its limited effectiveness in returning knee range of motion, and additional studies are required to investigate the effects of ESWT.

Level of evidence: II.

Keywords: ACL; Anterior cruciate ligament reconstruction; Continuous passive motion; Cryotherapy; Neuromuscular electrical stimulation; Shockwave therapy; Surface electromyographic biofeedback.

PubMed Disclaimer

References

    1. Clin Orthop Relat Res. 1996 Oct;(331):93-101 - PubMed
    1. Phys Ther. 1992 Apr;72(4):294-9 - PubMed
    1. Ann R Coll Surg Engl. 1992 Nov;74(6):412-6 - PubMed
    1. Orthop Nurs. 2002 Mar-Apr;21(2):61-6 - PubMed
    1. Phys Ther. 2003 Aug;83(8):713-21 - PubMed

Publication types

LinkOut - more resources