Efficient Construction of Volar Wrist Splints: A Biomechanical Study Comparing Splints of Different Material, Thickness, and Design
- PMID: 27698633
- PMCID: PMC5030856
- DOI: 10.1177/1558944715627213
Efficient Construction of Volar Wrist Splints: A Biomechanical Study Comparing Splints of Different Material, Thickness, and Design
Abstract
Background: The aim was to test the null hypothesis that splint material, thickness, or longitudinal ridging does not affect the strength of a wrist splint. Methods: Ten splints were made according to each of 7 different splint designs (resulting in 7 groups of 10 splints each). All splints were the same length and were molded to approximate the contour of the volar hand, wrist, and forearm with the wrist in neutral. Three groups consisted of plaster splints of different thicknesses (8, 10, and 12 ply). Three additional groups included splints of the same thicknesses but with a longitudinal ridge. A single group was constructed from prefabricated fiberglass splinting material and did not involve a longitudinal ridge. Five splints in each group were subjected to 3-point bending mimicking flexion of the wrist and 5 were subjected to a 3-point bend mimicking wrist extension. Splints were loaded to failure using a servohydraulic load frame. Analysis of variance was used to compare splints. Results: Among the plaster splints, more layers of material and longitudinal ridging increased splint strength. Ridged 8-ply plaster splints exceeded the strength of nonridged 10-ply plaster splints. Ridged 8-ply plaster splints were similar in strength to fiberglass splints. Conclusions: The 8-ply ridged plaster splints may be a lighter, effective, and cheaper alternative to more common splint designs.
Keywords: cost; hand; splint; wrist.
Conflict of interest statement
The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.
Figures
References
-
- Browner B, Jupiter J, Krettek C, Anderson P. Closed Fracture Management. In: Browner B, Jupiter J, Krettek C, Anderson P, eds. Skeletal Trauma: Basic Science, Management, and Reconstruction. 5th ed. Philadelphia: Saunders-Elsevier, 2015;121-176.
-
- Chow J, Hsu S, Kwok D, Reagh J. Application techniques for plaster of paris back slab, resting splint, and thumb spica using ridged reinforcement. J Emerg Nurs. 2013;39:e79-e81. - PubMed
-
- Hamilton SW, Aboud H. Finite element analysis, mechanical assessment and material comparison of two volar slab constructs. Injury. 2009;40:397-399. - PubMed
-
- Theopold C, Bush JA, Wilson SW, Bayat A. Optimal plaster conformation derived using a custom-made jig to obtain maximum strength of protective plaster of Paris for hand surgery. J Trauma. 2007;63:1074-1078. - PubMed
-
- Varian JP. The ridged plaster volar slab. Hand. 1975;7:78-80. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources