Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1989 Aug;29(2):143-50.
doi: 10.1016/0165-0270(89)90026-5.

Nerve fibre morphometry: a comparison of techniques

Affiliations
Comparative Study

Nerve fibre morphometry: a comparison of techniques

D P Ewart et al. J Neurosci Methods. 1989 Aug.

Abstract

This study compared different approaches to measuring nerve axon and fibre diameters and areas from transverse sections. A mock photomicrograph and mock tissue section, each with 100 identical, circular 'fibres' was constructed. Three measurement protocols were investigated: (A) circular approximation from minimum diameter; (B) circular approximation from the mean of orthogonal diameters; and (C) calculation of diameter and area from a digitized circumference. For each protocol, all 100 fibres on the photomicrograph were repeatedly measured using a digitizing tablet. Similarly, the fibres on the mock tissue section were measured using a digitizing tablet and microscope with camera lucida. The variance for these data was calculated. Protocols were compared on the basis of variability and the amount of digitizing time required. For diameter measurements, protocol B showed significantly lower variability than A or C (P less than 0.05), with only a modest increase in digitizing time over A. For area measurements, protocols B and C showed significantly lower variability than A (P less than 0.05), again with a modest increase in digitizing time. Measurements made using the microscope and camera lucida showed significantly lower variability than those made from the photomicrograph, but took more time. These data suggest that for diameter measurements, a mean of orthogonal diameters approach is best, and that for area measurements, a traced circumference approach is best as it is more flexible than the orthogonal diameter approach. While the microscope and camera lucida setup is more time-consuming to use, it eliminates the need for photomicrograph production.

PubMed Disclaimer

Publication types

LinkOut - more resources