Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2017 Mar;28(3):461-467.
doi: 10.1007/s00192-016-3128-z. Epub 2016 Oct 6.

Transobturator versus single incision slings: 1-year results of a randomized controlled trial

Affiliations
Randomized Controlled Trial

Transobturator versus single incision slings: 1-year results of a randomized controlled trial

Aimee L Tieu et al. Int Urogynecol J. 2017 Mar.

Abstract

Introduction and hypothesis: To compare 1-year surgical outcomes following transobturator (TO) sling placement and single incision (SI) sling placement for the treatment of stress urinary incontinence (SUI).

Methods: We performed a randomized trial at a single institution. Patients with urodynamically proven SUI were offered participation and randomized to placement of a TO sling (Monarc™) or a SI sling (MiniArc™) between 2008 and 2011. The primary outcome measure was urinary leakage during standardized cough stress test (CST). Forty subjects in each group were required to achieve 80 % power to detect an effect size of 0.25.

Results: A total of 98 patients were randomized with 49 patients in the TO group and 49 patients in the SI group. Preoperative demographics were similar between the groups (Table 1). The TO group had a significantly longer sling operative time (10.7 ± 4.8 min vs. 7.8 ± 4.9 min, p < 0.001) and greater estimated blood loss (31.6 ± 26.6 mL vs. 22.9 ± 22.1 mL, p = 0.02). At the 1-year follow-up, there was no difference in the primary outcome with 9 TO patients (21 %) and 12 SI patients (29 %) having a positive CST (p = 0.5). A composite measurement of 'failure', defined as patient-reported SUI and a positive CST, showed no difference between the TO group (17 %) and the SI group (27 %; p = 0.3).

Conclusions: The SI sling provides comparable objective efficacy to the TO sling at 1 year.

Keywords: Single incision slings; Stress incontinence; Transobturator slings.

PubMed Disclaimer

References

    1. Am J Obstet Gynecol. 2011 Sep;205(3):230.e1-5 - PubMed
    1. Obstet Gynecol. 2014 Jun;123(6):1201-6 - PubMed
    1. Surg Technol Int. 2009 Apr;18:175-81 - PubMed
    1. Int Urogynecol J Pelvic Floor Dysfunct. 2006 Sep;17(5):460-5 - PubMed
    1. Int Urogynecol J. 2010 Feb;21(2):149-55 - PubMed

Publication types

LinkOut - more resources