Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2016 Dec;103(13):1758-1767.
doi: 10.1002/bjs.10308. Epub 2016 Oct 7.

Meta-analysis of the use of surgical sealants for suture-hole bleeding in arterial anastomoses

Affiliations
Meta-Analysis

Meta-analysis of the use of surgical sealants for suture-hole bleeding in arterial anastomoses

A C Rogers et al. Br J Surg. 2016 Dec.

Abstract

Background: Suture-hole bleeding in arterial anastomoses prolongs operating time and increases blood loss, particularly with the use of prosthetic grafts. Surgical sealants (such as fibrin) may be used as haemostatic adjuncts in vascular surgery. This is a systematic review and meta-analysis of published studies that investigated the utility of surgical sealants in arterial-to-prosthetic graft anastomoses.

Methods: A systematic review was undertaken of papers published until January 2015 on Embase, MEDLINE, PubMed, PubMed Central and Cochrane databases that analysed the use of surgical sealants as haemostatic adjuncts after arterial anastomoses. RCTs were included, with study endpoints of time to haemostasis or haemostasis at 5 min. Secondary outcomes included treatment failure, mean difference in estimated blood loss and duration of surgery. Sensitivity and subgroup analyses were performed, as well as funnel plot analysis for publication bias.

Results: A total of 2513 citations were reviewed; 19 RCTs comprising 1560 patients were ultimately included in the analysis. The majority of studies compared fibrin sealant with control haemostatic measures. Pooled analysis suggested that surgical sealants reduced the time to haemostasis (mean difference 243·26 (95 per cent c.i. 183·99 to 302·53) s; P < 0·001), improved haemostasis at 5 min (odds ratio 4·50, 95 per cent c.i. 2·59 to 7·81; P < 0·001), and were associated with less treatment failure, blood loss and shorter duration of surgery.

Conclusion: Surgical sealants appear to reduce suture-hole bleeding significantly in vascular prosthetic graft anastomoses compared with standard haemostatic measures.

PubMed Disclaimer

MeSH terms

LinkOut - more resources