Clinical Trial
. 2017 Apr;32(4):408-418.
doi: 10.1007/s00380-016-0897-8. Epub 2016 Oct 11.

Internet-based training of coronary artery patients: the Heart Cycle Trial

Affiliations
Free article
Clinical Trial

Internet-based training of coronary artery patients: the Heart Cycle Trial

Erik Skobel et al. Heart Vessels. 2017 Apr.
Free article

Abstract

Low adherence to cardiac rehabilitation (CR) might be improved by remote monitoring systems that can be used to motivate and supervise patients and tailor CR safely and effectively to their needs. The main objective of this study was to evaluate the feasibility of a smartphone-guided training system (GEX) and whether it could improve exercise capacity compared to CR delivered by conventional methods for patients with coronary artery disease (CAD). A prospective, randomized, international, multi-center study comparing CR delivered by conventional means (CG) or by remote monitoring (IG) using a new training steering/feedback tool (GEx System). This consisted of a sensor monitoring breathing rate and the electrocardiogram that transmitted information on training intensity, arrhythmias and adherence to training prescriptions, wirelessly via the internet, to a medical team that provided feedback and adjusted training prescriptions. Exercise capacity was evaluated prior to and 6 months after intervention. 118 patients (58 ± 10 years, 105 men) with CAD referred for CR were randomized (IG: n = 55, CG: n = 63). However, 15 patients (27 %) in the IG and 18 (29 %) in the CG withdrew participation and technical problems prevented a further 21 patients (38 %) in the IG from participating. No training-related complications occurred. For those who completed the study, peak VO2 improved more (p = 0.005) in the IG (1.76 ± 4.1 ml/min/kg) compared to CG (-0.4 ± 2.7 ml/min/kg). A newly designed system for home-based CR appears feasible, safe and improves exercise capacity compared to national CR. Technical problems reflected the complexity of applying remote monitoring solutions at an international level.

Keywords: Cardiac rehabilitation; Exercise training; Monitoring.

PubMed Disclaimer

References

    1. Heart. 2009 Jan;95(1):36-42 - PubMed
    1. J Am Coll Cardiol. 2016 Jan 5;67(1):13-5 - PubMed
    1. Prog Cardiovasc Dis. 2014 Mar-Apr;56(5):530-5 - PubMed
    1. Am J Cardiol. 2000 Jul 1;86(1):17-23 - PubMed
    1. Mayo Clin Proc. 2009 Apr;84(4):373-83 - PubMed

Publication types

MeSH terms