Does C-MAC® video laryngoscope improve the nasotracheal intubating conditions compared to Macintosh direct laryngoscope in paediatric patients posted for tonsillectomy surgeries?

Affiliations

Does C-MAC® video laryngoscope improve the nasotracheal intubating conditions compared to Macintosh direct laryngoscope in paediatric patients posted for tonsillectomy surgeries?

Vinuta V Patil et al. Indian J Anaesth. 2016 Oct.

Abstract

Background and aims: C-MAC® video laryngoscope (VL) with Macintosh blade has been found to improve Cormack-Lehane (C-L) laryngoscopic view as well as intubating conditions for orotracheal intubation. However, studies done on the performance of C-MAC® VL for nasotracheal intubation (NTI) are very few in number. Hence, we compared laryngoscopy and intubating conditions between Macintosh direct laryngoscope and C-MAC® VL for NTI.

Methods: Sixty American Society of Anesthesiologists Physical Status I, II patients, aged 8-18 years, posted for tonsillectomy surgeries under general anaesthesia with NTI were randomised, into two groups. Patients in group 1 were intubated using Macintosh direct laryngoscope and group 2 with C-MAC® VL. C-L grading, time required for intubation, need for additional manoeuvres and haemodynamic changes during and after intubation were compared between the groups.

Results: C-L grade 1 views were obtained in 26 and 29 patients in group 1 and group 2, respectively (86.7% vs. 96.7%). Remaining patients were having C-L grade 2 (13.3% vs. 3.3%). Duration of intubation was less than a minute in group 2 (93.3%). Need for additional manoeuvres (M1-M5) were more in group 1 (97% vs. 77%). M1 (external manipulation) was needed more in group 2 compared to group 1 (53.3% vs. 30%). Magill's forceps alone (M4) and M4 with additional external manipulation (M5) were needed more in group 1 compared to group 2 (60% vs. 16%).

Conclusion: The overall performance of C-MAC® VL was better when compared to conventional direct Macintosh laryngoscope during NTI in terms of glottis visualisation, intubation time and need for additional manoeuvres.

Keywords: C-MAC® video laryngoscope; Macintosh direct laryngoscope; nasotracheal intubation.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Comparison of intubation time between the groups
Figure 2
Figure 2
Comparision of intubating conditions between group1 and group 2. (M3 = Combined use of cuff inflation with external laryngeal manipulation was not useful in both the groups)

References

    1. Lim Y, Lim TJ, Liu EH. Ease of intubation with the GlideScope or Macintosh laryngoscope by inexperienced operators in simulated difficult airways. Can J Anaesth. 2004;51:641–2. - PubMed
    1. Low D, Healy D, Rasburn N. The use of the BERCI DCI Video Laryngoscope for teaching novices direct laryngoscopy and tracheal intubation. Anaesthesia. 2008;63:195–201. - PubMed
    1. Kaplan MB, Ward DS, Berci G. A new video laryngoscope-an aid to intubation and teaching. J Clin Anesth. 2002;14:620–6. - PubMed
    1. Kaplan MB, Hagberg CA, Ward DS, Brambrink A, Chhibber AK, Heidegger T, et al. Comparison of direct and video-assisted views of the larynx during routine intubation. J Clin Anesth. 2006;18:357–62. - PubMed
    1. Enomoto Y, Asai T, Arai T, Kamishima K, Okuda Y. Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: A randomized comparative study. Br J Anaesth. 2008;100:544–8. - PubMed