Observational Study
. 2017 Feb;33(2):177-186.
doi: 10.1007/s10554-016-1001-2. Epub 2016 Oct 19.

Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography

Affiliations
Observational Study

Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography

Hirofumi Ohtani et al. Int J Cardiovasc Imaging. 2017 Feb.

Abstract

Few studies have directly compared vascular responses to second-generation drug-eluting stents (DESs). We performed optical coherence tomography examinations in 56 consecutive patients with implanted single stent [19 cobalt-chromium everolimus-eluting stents (CoCr-EES), 22 platinum-chromium EES (PtCr-EES), and 15 resolute zotarolimus-eluting stents (R-ZES)] for de novo lesions, and who did not have restenosis at their 9-month follow-up. Neointimal thickness (NIT), stent apposition, and neointimal coverage were assessed in every strut. A neointimal unevenness score [(NUS), maximum NIT/average NIT in the same cross-section] was determined for every 1-mm cross-section (CS). A total of 8350 struts and 1159 CSs were analyzed. The CoCr- and PtCr-EES had significantly fewer malapposed struts compared to the R-ZES (CoCr-EES: 0.19 % vs. PtCr-EES: 0.19 % vs.

R-zes: 0.61 %, p = 0.007). Furthermore, the PtCr-EES had a lower frequency of uncovered struts compared to the others (CoCr-EES: 2.0 % vs. PtCr-EES: 1.4 % vs.

R-zes: 2.3 %, p = 0.047). The NUS correlated with the frequency of uncovered struts (p < 0.001, r = 0.54). The EESs demonstrated more homogenous neointimal growth, as shown in the NUS, compared to the R-ZES [CoCr-EES: 1.66 (1.38-1.97) vs. PtCr-EES: 1.67 (1.41-2.00) vs.

R-zes: 1.94 (1.56-2.28), p < 0.001]. Our results demonstrate that unevenness neointimal growth may relate with strut coverage after second-generation DES implantation. The PtCr-EES had a high frequency of strut coverage with a homogeneous neointima, suggesting fewer risks for stent thrombosis.

Keywords: Neointimal hyperplasia; Optical coherence tomography; Second-generation drug-eluting stent; Strut coverage.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Catheter Cardiovasc Interv. 2013 Feb;81(3):510-8 - PubMed
    1. J Am Coll Cardiol. 2011 Apr 19;57(16):1700-8 - PubMed
    1. Int J Cardiol. 2011 Feb 3;146(3):341-6 - PubMed
    1. JACC Cardiovasc Interv. 2013 Dec;6(12):1267-74 - PubMed
    1. EuroIntervention. 2016 Dec 10;12 (11):e1366-e1374 - PubMed

Publication types

MeSH terms

LinkOut - more resources