Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Dec;69(12):1598-1608.
doi: 10.1016/j.bjps.2016.09.017. Epub 2016 Sep 28.

Outcome after urgent microvascular revision of free DIEP, SIEA and SGAP flaps for autologous breast reconstruction

Affiliations

Outcome after urgent microvascular revision of free DIEP, SIEA and SGAP flaps for autologous breast reconstruction

A Vanschoonbeek et al. J Plast Reconstr Aesthet Surg. 2016 Dec.

Abstract

Introduction: Microvascular complications after free flap breast reconstruction are devastating, and revision of a compromised breast reconstruction is very challenging. The aim of this study was to review the different characteristics of urgent microvascular revision in DIEP, SIEA and SGAP flaps and to evaluate the final outcome after revision.

Materials and methods: A retrospective chart review was performed for all patients who underwent an autologous breast reconstruction with a DIEP, SIEA or SGAP flap at the University Hospitals of Leuven between August 1997 and December 2013. The number of revisions, time to revision, reason for revision, and outcome after microvascular free flap revision were analysed.

Results: A total of 1562 free flaps were evaluated during the study period, of which 4.42% required urgent exploration. DIEP flaps (3.38%) had a statistically significant lower revision rate than SIEA flaps (11.76%) and SGAP flaps (8.42%). Venous insufficiency was the main reason for revision of DIEP flaps (86.7%) and SGAP flaps (62.5%). SIEA flaps mostly failed because of an arterial problem (62.5%). SIEA flaps (62.5%) had a higher revision failure rate than DIEP flaps (37.8%) and SGAP flaps (12.5%). We found a statistically significant difference (p < 0.001) in the outcome of revision in DIEP flaps in correlation to the time to revision. Our overall flap failure rate was 1.79% (DIEP 1.28%; SIEA 7.35%; SGAP 1.05%).

Conclusions: The DIEP flap remains the most reliable flap for microvascular breast reconstructions. SIEA flaps are only performed when no suitable perforator for a DIEP flap is present. Multiple revisions are no longer performed, as the outcome after more than one revision is very disappointing. The difference in reason for revision between the different flaps led to the introduction of some technical refinements.

Keywords: Breast reconstruction; Microvascular free flap; Outcome; Revision; Salvage.