Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2017 Jan:23:105-112.
doi: 10.1016/j.ptsp.2016.08.007. Epub 2016 Aug 12.

Ultrasound evaluation of the subacromial space in healthy subjects performing three different positions of shoulder abduction in both loaded and unloaded conditions

Affiliations
Randomized Controlled Trial

Ultrasound evaluation of the subacromial space in healthy subjects performing three different positions of shoulder abduction in both loaded and unloaded conditions

Stefano Longo et al. Phys Ther Sport. 2017 Jan.

Abstract

Background: Subacromial space (SS) narrowing may result in unsafe contact of rotator cuff tendons and bursa with the acromion, possibly promoting rotator cuff pathologies and pain. We measured SS in asymptomatic subjects after three movements employed for shoulder muscles' training.

Participants and main outcome measures: Twenty-five males (age 24±5years; stature 175±8 cm; body mass 74±12 kg) underwent SS ultrasound evaluation while executing with (WL) and without (NL) 4-kg load: 90° shoulder abduction (SA) without humerus rotation (90°neutral); 90° SA maximal humeral external rotation (90°er); maximum SA (above 90°) during upright row (UR). For inter-operator reliability analysis, a subset of 12 subjects was assessed by two operators.

Results: Intra/inter-operator reliability coefficients were high (ICC>0.87; standard error of measurement range: 0.23-0.51 mm; minimum detectable change range: 0.61-1.79 mm). ANOVA revealed significant differences between loads (p = 0.003, η2 = 0.37) and angles (p < 0.001, η2 = 0.72), and interaction (p = 0.004, η2 = 0.45). Normalized SS values WL were higher at 90°er vs. 90°neutral and UR (p < 0.001 for both). Differences in NL were found between 90°neutral and both 90°er (p = 0.002) and UR (p = 0.009).

Conclusions: When holding a 4-kg load, SS is larger at 90°er than at 90°neutral and UR shoulder abduction positions. In unloaded condition, SS at 90°neutral is reduced compared to 90°er and UR.

Keywords: Lateral rise; Subacromial space; Ultrasound; Upright row.

PubMed Disclaimer

Publication types

LinkOut - more resources