Higher resolution cine imaging with compressed sensing for accelerated clinical left ventricular evaluation
- PMID: 27783472
- DOI: 10.1002/jmri.25525
Higher resolution cine imaging with compressed sensing for accelerated clinical left ventricular evaluation
Abstract
Purpose: To assess the clinical feasibility of a compressed sensing cine magnetic resonance imaging (MRI) sequence of both high temporal and spatial resolution (CS_bSSFP) in comparison to a balanced steady-state free precession cine (bSSFP) sequence for reliable quantification of left ventricular (LV) volumes and mass.
Materials and methods: Segmented MRI cine images were acquired on a 1.5T scanner in 50 patients in the LV short-axis stack orientation using a retrospectively gated conventional bSSFP sequence (generalized autocalibrating partially parallel acquisition [GRAPPA] acceleration factor 2), followed by a prospectively triggered CS_bSSFP sequence with net acceleration factor of 8. Image quality was assessed by published criteria. Comparison of sequences was made in LV volumes and mass, image quality score, quantitative regional myocardial wall motion, and imaging time using Pearson's correlation, Bland-Altman and paired 2-tailed Student's t-test.
Results: Differences (bSSFP minus CS_bSSFP, mean ± SD) and Pearson's correlations were 14.8 ± 16.3 (P = 0.31) and r = 0.98 (P < 0.0001) for end-diastolic volume (EDV), 8.4 ± 11.3 (P = 0.54) and r = 0.99 (P < 0.0001) for end-systolic volume (ESV), -0.4 ± 2.5 (P = 0.87) and r = 0.97 (P < 0.0001) for EF, and -0.9 ± 11.8 (P = 0.92) and r = 0.97 (P < 0.0001) for LV mass. Bland-Altman analyses [bias and (limits of agreement)] revealed strong agreement in LVEDV [8.7 ml, (-12.1, 29.6)], LVESV [4.3 ml, (-11.9, 20.6)], LVEF [-0.02%, (-5.37, 5.33)], and myocardial mass [-6.1 g, (-14.7, 26.9)]. Image quality was comparable with a similar mean score (P = 0.42), with a good correlation in image quality observed (r = 0.68, P < 0.0001). Quantitative regional myocardial wall motion demonstrated strong correlation between the sequences (r = 0.87, P < 0.0001). Imaging time was significantly shorter for the CS_bSSFP sequence (1.1 ± 0.5 versus 5.6 ± 1.6 min, P < 0.0001).
Conclusion: The novel high-resolution cine CS_bSSFP accurately and reliably quantitates LV volumes and mass, shortens acquisition times, and is clinically feasible.
Level of evidence: 1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;45:1693-1699.
Keywords: bSSFP; cardiac magnetic resonance; compressed sensing; left ventricle.
© 2016 International Society for Magnetic Resonance in Medicine.
Similar articles
-
Compressed sensing cine imaging with high spatial or high temporal resolution for analysis of left ventricular function.J Magn Reson Imaging. 2016 Aug;44(2):366-74. doi: 10.1002/jmri.25162. Epub 2016 Jan 20. J Magn Reson Imaging. 2016. PMID: 26789014
-
Single breath hold 3D cardiac cine MRI using kat-ARC: preliminary results at 1.5T.Int J Cardiovasc Imaging. 2015 Apr;31(4):851-7. doi: 10.1007/s10554-015-0615-0. Epub 2015 Feb 14. Int J Cardiovasc Imaging. 2015. PMID: 25680356
-
Assessment of the precision and reproducibility of ventricular volume, function, and mass measurements with ferumoxytol-enhanced 4D flow MRI.J Magn Reson Imaging. 2016 Aug;44(2):383-92. doi: 10.1002/jmri.25180. Epub 2016 Feb 12. J Magn Reson Imaging. 2016. PMID: 26871420 Free PMC article.
-
Clinical Applications of Cine Balanced Steady-State Free Precession MRI for the Evaluation of the Subarachnoid Spaces.Clin Neuroradiol. 2015 Dec;25(4):349-60. doi: 10.1007/s00062-015-0383-1. Epub 2015 Apr 9. Clin Neuroradiol. 2015. PMID: 25854921 Review.
-
Practical applications of balanced steady-state free-precession (bSSFP) imaging in the abdomen and pelvis.J Magn Reson Imaging. 2017 Jan;45(1):11-20. doi: 10.1002/jmri.25336. Epub 2016 Jul 4. J Magn Reson Imaging. 2017. PMID: 27373694 Review.
Cited by
-
Free-breathing, Highly Accelerated, Single-beat, Multisection Cardiac Cine MRI with Generative Artificial Intelligence.Radiol Cardiothorac Imaging. 2025 Apr;7(2):e240272. doi: 10.1148/ryct.240272. Radiol Cardiothorac Imaging. 2025. PMID: 40178397
-
Compressed sensing acceleration of cardiac cine imaging allows reliable and reproducible assessment of volumetric and functional parameters of the left and right atrium.Eur Radiol. 2021 Oct;31(10):7219-7230. doi: 10.1007/s00330-021-07830-z. Epub 2021 Mar 29. Eur Radiol. 2021. PMID: 33779815 Free PMC article.
-
Breath-hold and free-breathing quantitative assessment of biventricular volume and function using compressed SENSE: a clinical validation in children and young adults.J Cardiovasc Magn Reson. 2020 Jul 27;22(1):54. doi: 10.1186/s12968-020-00642-y. J Cardiovasc Magn Reson. 2020. PMID: 32713347 Free PMC article.
-
Prognosis in patients with coronary heart disease and breath-holding limitations: a free-breathing cardiac magnetic resonance protocol at 3.0 T.BMC Cardiovasc Disord. 2021 Dec 7;21(1):580. doi: 10.1186/s12872-021-02402-x. BMC Cardiovasc Disord. 2021. PMID: 34876015 Free PMC article.
-
Breakthroughs in modern cancer therapy and elusive cardiotoxicity: Critical research-practice gaps, challenges, and insights.Med Res Rev. 2018 Jan;38(1):325-376. doi: 10.1002/med.21463. Epub 2017 Sep 1. Med Res Rev. 2018. PMID: 28862319 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials