Effects of trunk stability on isometric knee extension muscle strength measurement while sitting
- PMID: 27799673
- PMCID: PMC5080155
- DOI: 10.1589/jpts.28.2474
Effects of trunk stability on isometric knee extension muscle strength measurement while sitting
Abstract
[Purpose] This study aimed to investigate the effect of trunk stability on isometric knee extension muscle strength measurement while sitting by performing simultaneous measurements with a handheld dynamometer (HHD) and an isokinetic dynamometer (IKD) in the same seated condition. [Subjects and Methods] The subjects were 30 healthy volunteers. Isometric knee extension muscle strength was simultaneously measured with a HHD and an IKD by using an IKD-specific chair. The measurement was performed twice. Measurement instrument variables and the number of measurements were examined by using the analysis of variance and correlation tests. [Results] The measurement instrument variables and the number of measurements were not significantly different. The correlation coefficients between the HHD and IKD measurements were ≥0.96. [Conclusion] Isometric knee extension muscle strength measurement using the HHD in the sitting position resulted in a lower value than that using the IKD, presumably because of the effect of trunk stability on the measurement. In the same seated posture with trunk stability, no significant difference in measurement values was observed between the HHD and IKD. The present findings suggest that trunk stability while seated during isometric knee extension muscle strength measurement influenced the HHD measurement.
Keywords: Handheld dynamometer; Isokinetic dynamometer; Knee extension muscle strength.
References
-
- Katoh M, Kaneko Y: An investigation into reliability of knee extension muscle strength measurements, and into the relationship between muscle strength and means of independent mobility in the ward: examinations of patients who underwent femoral neck fracture surgery. J Phys Ther Sci, 2014, 26: 15–19. - PMC - PubMed
-
- Hyde SA, Goddard CM, Scott OM: The myometer: the development of a clinical tool. Physiotherapy, 1983, 69: 424–427. - PubMed
-
- Katoh M, Yamasaki H: Comparison of reliability of isometric leg muscle strength measurements made using a hand-held dynamometer with and without a restraining belt. J Phys Ther Sci, 2009, 21: 37–42.
-
- Katoh M, Yamasaki H: Test-retest reliability of isometric leg muscle strength measurements made using a hand-held dynamometer restrained by a belt: comparisons during and between sessions. J Phys Ther Sci, 2009, 21: 239–243.
LinkOut - more resources
Full Text Sources
Other Literature Sources