Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Jan 3;166(1):27-36.
doi: 10.7326/M16-0462. Epub 2016 Nov 1.

Diagnosis of Gout: A Systematic Review in Support of an American College of Physicians Clinical Practice Guideline

Affiliations
Free article

Diagnosis of Gout: A Systematic Review in Support of an American College of Physicians Clinical Practice Guideline

Sydne J Newberry et al. Ann Intern Med. .
Free article

Abstract

Background: Alternative strategies exist for diagnosing gout that do not rely solely on the documentation of monosodium urate (MSU) crystals.

Purpose: To summarize evidence regarding the accuracy of clinical tests and classification algorithms compared with that of a reference standard of MSU crystals in joint aspirate for diagnosing gout.

Data sources: Several electronic databases from inception to 29 February 2016.

Study selection: 21 prospective cohort, cross-sectional, and case-control studies including participants with joint inflammation and no previous definitive gout diagnosis who had MSU analysis of joint aspirate.

Data extraction: Data extraction and risk-of-bias assessment by 2 reviewers independently; overall strength of evidence (SOE) judgment by group.

Data synthesis: Recently developed algorithms including clinical, laboratory, and imaging criteria demonstrated good sensitivity (up to 88%) and fair to good specificity (up to 96%) for diagnosing gout (moderate SOE). Three studies of dual-energy computed tomography (DECT) showed sensitivities of 85% to 100% and specificities of 83% to 92% for diagnosing gout (low SOE). Six studies of ultrasonography showed sensitivities of 37% to 100% and specificities of 68% to 97%, depending on the ultrasonography signs assessed (pooled sensitivity and specificity for the double contour sign: 74% [95% CI, 52% to 88%] and 88% [CI, 68% to 96%], respectively [low SOE]).

Limitation: Important study heterogeneity and selection bias; scant evidence in primary and urgent care settings and in patients with conditions that may be confused with or occur with gout.

Conclusion: Multidimensional algorithms, which must be validated in primary and urgent care settings, may help clinicians make a provisional diagnosis of gout. Although DECT and ultrasonography also show promise for gout diagnosis, accessibility to these methods may be limited.

Primary funding source: Agency for Healthcare Research and Quality. (Protocol registration: https://effectivehealthcare.ahrq.gov/ehc/products/564/1937/gout-protocol-140716.pdf).

PubMed Disclaimer

Publication types

LinkOut - more resources