A randomised feasibility study comparing total hip arthroplasty with and without dual mobility acetabular component in the treatment of displaced intracapsular fractures of the proximal femur : The Warwick Hip Trauma Evaluation Two : WHiTE Two
- PMID: 27803216
- DOI: 10.1302/0301-620X.98B11.BJJ-2016-0478.R1
A randomised feasibility study comparing total hip arthroplasty with and without dual mobility acetabular component in the treatment of displaced intracapsular fractures of the proximal femur : The Warwick Hip Trauma Evaluation Two : WHiTE Two
Abstract
Aims: The optimal treatment for independent patients with a displaced intracapsular fracture of the hip remains controversial. The recognised alternatives are hemiarthroplasty and total hip arthroplasty. At present there is no established standard of care, with both types of arthroplasty being used in many centres.
Patients and methods: We conducted a feasibility study comparing the clinical effectiveness of a dual mobility acetabular component compared with standard polyethylene component in total hip arthroplasty for independent patients with a displaced intracapsular fracture of the hip, for a 12-month period beginning in June 2013. The primary outcome was the risk of dislocation one year post-operatively. Secondary outcome measures were EuroQol 5 Dimensions, ICEpop CAPability measure for Older people, Oxford hip score, mortality and re-operation.
Results: Only 20 patients were recruited during this time. The baseline demographics were similar in the two groups and no patient suffered a dislocation. Differences in secondary outcomes were not analysed due to the small sample.
Conclusion: This feasibility study suggests that any trial investigating the effectiveness of total hip arthroplasty for fracture of the hip might not be deliverable within the constraints of current systems of care in the United Kingdom. Cite this article: Bone Joint J 2016;98-B:1431-5.
Keywords: Dual mobility; Hip fracture; Randomised controlled trial; Total hip arthroplasty.
©2016 The British Editorial Society of Bone & Joint Surgery.
Similar articles
-
Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation.Orthop Traumatol Surg Res. 2012 May;98(3):296-300. doi: 10.1016/j.otsr.2012.01.005. Epub 2012 Mar 29. Orthop Traumatol Surg Res. 2012. PMID: 22463868
-
Cost-effectiveness of dual-mobility components in patients with displaced femoral neck fractures.Bone Joint J. 2021 Dec;103-B(12):1783-1790. doi: 10.1302/0301-620X.103B12.BJJ-2021-0495.R2. Bone Joint J. 2021. PMID: 34847713
-
The Warwick Hip Trauma Evaluation Two -an abridged protocol for the WHiTE Two Study: An embedded randomised trial comparing the Dual-Mobility withpolyethylene cups in hip arthroplasty for fracture.Bone Joint Res. 2013 Oct 2;2(10):210-3. doi: 10.1302/2046-3758.210.2000186. Print 2013. Bone Joint Res. 2013. PMID: 24089291 Free PMC article.
-
Dual mobility total hip arthroplasty in the treatment of femoral neck fractures.Bone Joint J. 2020 Nov;102-B(11):1457-1466. doi: 10.1302/0301-620X.102B11.BJJ-2020-0610.R2. Bone Joint J. 2020. PMID: 33135437
-
Displaced intracapsular hip fractures: hemiarthroplasty or total arthroplasty?Clin Orthop Relat Res. 2002 Jun;(399):72-7. Clin Orthop Relat Res. 2002. PMID: 12011696 Review.
Cited by
-
Arthroplasties for hip fracture in adults.Cochrane Database Syst Rev. 2022 Feb 14;2(2):CD013410. doi: 10.1002/14651858.CD013410.pub2. Cochrane Database Syst Rev. 2022. PMID: 35156194 Free PMC article.
-
Surgical interventions for treating intracapsular hip fractures in older adults: a network meta-analysis.Cochrane Database Syst Rev. 2022 Feb 14;2(2):CD013404. doi: 10.1002/14651858.CD013404.pub2. Cochrane Database Syst Rev. 2022. PMID: 35156192 Free PMC article.
-
The reporting of outcomes in randomised controlled trials: The switch and the spin.Bone Joint Res. 2017 Oct;6(10):600-601. doi: 10.1302/2046-3758.610.BJR-2017-0296. Bone Joint Res. 2017. PMID: 29066533 Free PMC article. No abstract available.
-
A randomized controlled trial comparing the Thompson hemiarthroplasty with the Exeter polished tapered stem and Unitrax modular head in the treatment of displaced intracapsular fractures of the hip: the WHiTE 3: HEMI Trial.Bone Joint J. 2018 Mar 1;100-B(3):352-360. doi: 10.1302/0301-620X.100B3.BJJ-2017-0872.R2. Bone Joint J. 2018. PMID: 29589786 Free PMC article. Clinical Trial.
-
The efficacy of dual-mobility cup in preventing dislocation after total hip arthroplasty: a systematic review and meta-analysis of comparative studies.Int Orthop. 2019 May;43(5):1071-1082. doi: 10.1007/s00264-018-4062-0. Epub 2018 Jul 21. Int Orthop. 2019. PMID: 30032356
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical