. 2016 Nov 8;16(1):660.
doi: 10.1186/s12879-016-2009-x.

Diagnostic performance of smear microscopy and incremental yield of Xpert in detection of pulmonary tuberculosis in Rwanda

Affiliations

Diagnostic performance of smear microscopy and incremental yield of Xpert in detection of pulmonary tuberculosis in Rwanda

Jean Claude Semuto Ngabonziza et al. BMC Infect Dis. .

Abstract

Background: Tuberculosis control program of Rwanda is currently phasing in light emitting diode-fluorescent microscopy (LED-FM) as an alternative to Ziehl-Neelsen (ZN) smear microscopy. This, alongside the newly introduced Xpert (Cepheid, Sunnyvale, CA, USA) is expected to improve diagnosis of tuberculosis and detection of rifampicin resistance in patients at health facilities. We assessed the accuracy of smear microscopy and the incremental sensitivity of Xpert at tuberculosis laboratories in Rwanda.

Methods: This was a cross-sectional study involving four laboratories performing ZN and four laboratories performing LED-FM microscopy. The laboratories include four intermediate (ILs) and four peripheral (PLs) laboratories. After smear microscopy, the left-over of samples, of a single early-morning sputum from 648 participants, were tested using Xpert and mycobacterial culture as a reference standard. Sensitivity of each test was compared and the incremental sensitivity of Xpert after a negative smear was assessed.

Results: A total of 96 presumptive pulmonary tuberculosis participants were culture positive for M. tuberculosis. The overall sensitivity in PL of ZN was 55.1 % (40.2-69.3 %), LED-FM was 37 % (19.4-57.6 %) and Xpert was 77.6 % (66.6-86.4 %) whereas in ILs the same value for ZN was 58.3 % (27.7-84.8 %), LED-FM was 62.5 % (24.5-91.5 %) and Xpert was 90 (68.3-98.8 %). The sensitivity for all tests was significantly higher among HIV-negative individuals (all test p <0.05). The overall incremental sensitivity of Xpert over smear microscopy was 32.3 %; p < 0.0001. The incremental sensitivity of Xpert was statistically significant for both smear methods at PL (32.9 %; p = 0.001) but not at the ILs (30 %; p = 0.125) for both smear methods.

Conclusions: Our study findings of the early implementation of the LED-FM did not reveal significant increment in sensitivity compared to the method being phased out (ZN). This study showed a significant incremental sensitivity for Xpert from both smear methods at peripheral centers where majority of TB patients are diagnosed. Overall our findings support the recommendation for Xpert as an initial diagnostic test in adults and children presumed to have TB.

Keywords: Incremental yield of Xpert; LED-FM versus ZN; Tuberculosis diagnosis in Rwanda; Tuberculosis microscopy in routine conditions.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Flow chart showing series of participants’ recruitment and the outcome of different tuberculosis testing methods used. +: Positive, -: Negative, AFB: Acid Fast Bacilli, PTB: Pulmonary tuberculosis, ZN Lab: Ziehl Nelsen health facility laboratories-, LED-FM Lab: Light emitting diode-fluorescence microscopy using health facility laboratories, NTM: Non-tuberculous Mycobacteria, cont.: contaminated

References

    1. Drobniewski F, Balabanova Y, Nikolayevsky V, Ruddy M, Kuznetzov S, Zakharova S, Melentyev A, Fedorin I. Drug-resistant tuberculosis, clinical virulence, and the dominance of the Beijing strain family in Russia. JAMA. 2005;293(22):2726–2731. doi: 10.1001/jama.293.22.2726. - DOI - PubMed
    1. Islam MR, Khatun R, Uddin MK, Khan MS, Rahman MT, Ahmed T, Banu S. Yield of two consecutive sputum specimens for the effective diagnosis of pulmonary tuberculosis. PLoS One. 2013;8(7):e67678. doi: 10.1371/journal.pone.0067678. - DOI - PMC - PubMed
    1. Chaidir L, Parwati I, Annisa J, Muhsinin S, Meilana I, Alisjahbana B, van Crevel R. Implementation of LED fluorescence microscopy for diagnosis of pulmonary and HIV-associated tuberculosis in a hospital setting in Indonesia. PLoS One. 2013;8(4):e61727. doi: 10.1371/journal.pone.0061727. - DOI - PMC - PubMed
    1. Steingart KR, Sohn H, Schiller I, Kloda LA, Boehme CC, Pai M, Dendukuri N. Xpert(R) MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults. Cochrane Database Syst Rev. 2013;1:CD009593. - PMC - PubMed
    1. Steingart KR, Henry M, Ng V, Hopewell PC, Ramsay A, Cunningham J, Urbanczik R, Perkins M, Aziz MA, Pai M. Fluorescence versus conventional sputum smear microscopy for tuberculosis: a systematic review. Lancet Infect Dis. 2006;6(9):570–581. doi: 10.1016/S1473-3099(06)70578-3. - DOI - PubMed