Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement With the SAPIEN 3
- PMID: 27832845
- DOI: 10.1016/j.jcin.2016.08.034
Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement With the SAPIEN 3
Abstract
Objectives: The aim of this study was to identify predictors of permanent pacemaker implantation (PPMI) following transcatheter aortic valve replacement (TAVR) with a balloon-expandable transcatheter valve (Edwards SAPIEN 3).
Background: New-onset conduction disturbances requiring PPMI remain a major concern following TAVR. Predictors are not yet well defined.
Methods: The influence of angiographic implantation depth, device landing zone calcium volume, oversizing, pre- and post-dilation, and baseline conduction disturbances on PPMI rate was analyzed in 229 patients undergoing TAVR with the SAPIEN 3 device.
Results: PPMI was performed in 14.4% of patients. Patients requiring PPMI had higher left ventricular outflow tract (LVOT) calcium volume in the area below the left coronary cusp (LVOTLC) and the area below right coronary cusp (LVOTRC) (LVOTLC median calcium 23.7 mm3 vs. 3.0 mm3; p < 0.001; LVOTRC median calcium 6.6 mm3 vs. 0.3 mm3; p = 0.014), a higher prevalence of pre-existing right bundle branch block (15% vs. 2%, p = 0.004), and lower implantation depth (ventricular portion of the stent frame 29 ± 12% vs. 21 ± 5%; p < 0.001). On multivariate regression analysis, LVOTLC calcium volume >13.7 mm3, LVOTRC calcium volume >4.8 mm3, pre-existing right bundle branch block, and implantation depth >25.5% emerged as independent predictors of PPMI. Upon modification of the implantation technique, aiming at a high final valve position, implantation depth decreased from 24% ventricular portion to 21% (p = 0.012), accompanied by a decrease in PPMI rate (19.2% vs. 9.2%; p = 0.038).
Conclusions: LVOTLC and LVOTRC calcium load, baseline right bundle branch block, and implantation depth were identified as independent predictors of the need for PPMI post-TAVR. Patient groups with different PPMI risk could be stratified using these 4 predictors. A slightly higher valve implantation site may prevent excessive PPMI rates.
Keywords: SAPIEN 3; calcium distribution; permanent pacemaker implantation; transcatheter aortic valve replacement.
Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Comment in
-
Conduction Abnormalities: The True Achilles' Heel of Transcatheter Aortic Valve Replacement?JACC Cardiovasc Interv. 2016 Nov 14;9(21):2217-2219. doi: 10.1016/j.jcin.2016.09.040. JACC Cardiovasc Interv. 2016. PMID: 27832847 No abstract available.
Similar articles
-
A Highly Predictive Risk Model for Pacemaker Implantation After TAVR.JACC Cardiovasc Imaging. 2017 Oct;10(10 Pt A):1139-1147. doi: 10.1016/j.jcmg.2016.11.020. Epub 2017 Apr 12. JACC Cardiovasc Imaging. 2017. PMID: 28412434
-
Prosthesis depth and conduction disturbances after last generation balloon-expandable transcatheter aortic valve implantation.Europace. 2018 Jan 1;20(1):116-123. doi: 10.1093/europace/euw310. Europace. 2018. PMID: 28339584
-
Computed tomography (CT) assessment of the membranous septal anatomy prior to transcatheter aortic valve replacement (TAVR) with the balloon-expandable SAPIEN 3 valve.Cardiovasc Revasc Med. 2018 Jul-Aug;19(5 Pt B):626-631. doi: 10.1016/j.carrev.2017.12.012. Epub 2017 Dec 27. Cardiovasc Revasc Med. 2018. PMID: 29352699
-
Predictors of permanent pacemaker insertion after TAVR: A systematic review and updated meta-analysis.J Cardiovasc Electrophysiol. 2021 May;32(5):1411-1420. doi: 10.1111/jce.14986. Epub 2021 Mar 17. J Cardiovasc Electrophysiol. 2021. PMID: 33682218
-
Predictors for the risk of permanent pacemaker implantation after transcatheter aortic valve replacement: A systematic review and meta-analysis.J Card Surg. 2022 Feb;37(2):377-405. doi: 10.1111/jocs.16129. Epub 2021 Nov 14. J Card Surg. 2022. PMID: 34775652
Cited by
-
Temporal trends of TAVI treatment characteristics in high volume centers in Germany 2013-2020.Clin Res Cardiol. 2022 Aug;111(8):881-888. doi: 10.1007/s00392-021-01963-3. Epub 2021 Nov 9. Clin Res Cardiol. 2022. PMID: 34751789 Free PMC article.
-
A computational framework for post-TAVR cardiac conduction abnormality (CCA) risk assessment in patient-specific anatomy.Artif Organs. 2022 Jul;46(7):1305-1317. doi: 10.1111/aor.14189. Epub 2022 Feb 7. Artif Organs. 2022. PMID: 35083748 Free PMC article.
-
Hemodynamic effect of supra-annular implantation of SAPIEN 3 balloon expandable valve.Cardiovasc Interv Ther. 2025 Jan;40(1):133-143. doi: 10.1007/s12928-024-01040-2. Epub 2024 Sep 6. Cardiovasc Interv Ther. 2025. PMID: 39240505 Free PMC article.
-
Mid-term outcomes of Sapien 3 versus Perimount Magna Ease for treatment of severe aortic stenosis.J Cardiothorac Surg. 2020 Jun 29;15(1):157. doi: 10.1186/s13019-020-01203-1. J Cardiothorac Surg. 2020. PMID: 32600369 Free PMC article.
-
Loss of His-bundle and Right Ventricular Septal Capture Following Transcatheter Aortic Valve Replacement-A Case Report.J Innov Card Rhythm Manag. 2023 Feb 15;14(2):5332-5337. doi: 10.19102/icrm.2023.14022. eCollection 2023 Feb. J Innov Card Rhythm Manag. 2023. PMID: 36874558 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical