Cost-benefit analysis of establishing an inferior vena cava filter clinic
- PMID: 27833068
- PMCID: PMC5214074
- DOI: 10.5152/dir.2016.16007
Cost-benefit analysis of establishing an inferior vena cava filter clinic
Abstract
Purpose: Adverse events associated with retrievable inferior vena cava filters (IVCFs) have generated an increased interest in improving IVCF retrieval rates to improve patient safety and quality care. This study aims to demonstrate the cost-benefit of implementing an IVCF clinic to improve patient care in an institution in the United States.
Methods: An IVCF clinic was established at a single institution in September 2012 and for ten months referring physicians were contacted to facilitate retrieval when appropriate. Additionally, a retrospective review was conducted on filter placements over the eight preclinic months. Cost-benefit analysis was conducted by creating a model, which incorporated the average cost and reimbursement for permanent and retrievable IVCFs.
Results: A total of 190 IVCFs (152 retrievable IVCFs and 38 permanent IVCFs) were implanted during the IVCF clinic period. Twenty-nine percent of the retrievable IVCFs were successfully retrieved compared to 10 of 119 retrievable IVCFs placed during the preclinic period (8.4%). Cost-benefit analysis, using the average of the institution's six most common reimbursement schedules, demonstrated an average net financial loss per permanent or retrievable IVCF not removed. However, a net financial gain was realized for each retrievable IVCF removed. The additional hospital cost to maintain the IVCF clinic was offset by removing an additional 3.1 IVCFs per year.
Conclusion: An IVCF clinic significantly increases retrieval rates, promotes patient safety, and is economically feasible. Given the adverse event profile of retrievable IVCFs, strategic efforts such as these ultimately can improve quality care for patients with in-dwelling IVCFs.
Conflict of interest statement
disclosure The authors declared no conflicts of interest.
References
- 
    - Helling TS, Kaswan S, Miller SL, Tretter JF. Practice patterns in the use of retrievable inferior vena cava filters in a trauma population: A single-center experience. J Trauma. 2009;67:1293–1296. file:///doi.org/10.1097/TA.0b013e3181b0637a. - PubMed
 
- 
    - Tschoe M, Kim HS, Brotman DJ, Streiff MB. Retrievable vena cava filters: a clinical review. J Hosp Med. 2009;4:441–448. file:///doi.org/10.1002/jhm.439. - PubMed
 
- 
    - Athanasoulis CA, Kaufman JA, Halpern EF, Waltman AC, Geller SC, Fan CM. Inferior vena caval filters: Review of a 26-year single-center clinical experience. Radiology. 2000;216:54–66. file:///doi.org/10.1148/radiology.216.1.r00jl1254. - PubMed
 
- 
    - Van Ha TG. Complications of inferior vena caval filters. Semin Intervent Radiol. 2006;23:150–155. file:///doi.org/10.1055/s-2006-941445. - PMC - PubMed
 
- 
    - Removing retrievable inferior vena cava filters: initial communication. United States Food and Drug Administration Alerts and Notices (Medical Devices); [Accessed 6 May 2014]. http://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm396377.htm.
 
MeSH terms
LinkOut - more resources
- Full Text Sources
- Other Literature Sources
 
        