. 2017 Jan;38(1):103-114.
doi: 10.1007/s00246-016-1489-1. Epub 2016 Nov 11.

Utility and Scope of Rapid Prototyping in Patients with Complex Muscular Ventricular Septal Defects or Double-Outlet Right Ventricle: Does it Alter Management Decisions?

Affiliations

Utility and Scope of Rapid Prototyping in Patients with Complex Muscular Ventricular Septal Defects or Double-Outlet Right Ventricle: Does it Alter Management Decisions?

Puneet Bhatla et al. Pediatr Cardiol. 2017 Jan.

Abstract

Rapid prototyping facilitates comprehension of complex cardiac anatomy. However, determining when this additional information proves instrumental in patient management remains a challenge. We describe our experience with patient-specific anatomic models created using rapid prototyping from various imaging modalities, suggesting their utility in surgical and interventional planning in congenital heart disease (CHD). Virtual and physical 3-dimensional (3D) models were generated from CT or MRI data, using commercially available software for patients with complex muscular ventricular septal defects (CMVSD) and double-outlet right ventricle (DORV). Six patients with complex anatomy and uncertainty of the optimal management strategy were included in this study. The models were subsequently used to guide management decisions, and the outcomes reviewed. 3D models clearly demonstrated the complex intra-cardiac anatomy in all six patients and were utilized to guide management decisions. In the three patients with CMVSD, one underwent successful endovascular device closure following a prior failed attempt at transcatheter closure, and the other two underwent successful primary surgical closure with the aid of 3D models. In all three cases of DORV, the models provided better anatomic delineation and additional information that altered or confirmed the surgical plan. Patient-specific 3D heart models show promise in accurately defining intra-cardiac anatomy in CHD, specifically CMVSD and DORV. We believe these models improve understanding of the complex anatomical spatial relationships in these defects and provide additional insight for pre/intra-interventional management and surgical planning.

Keywords: 3D printing; Computed tomography; Congenital heart disease; Double-outlet right ventricle; Magnetic resonance imaging; Rapid prototyping; Ventricular septal defect.

PubMed Disclaimer

References

    1. Ann Thorac Surg. 2008 Jul;86(1):273-7 - PubMed
    1. J Cardiovasc Magn Reson. 2013 Jan 16;15:2 - PubMed
    1. Circulation. 2005 Dec 13;112(24):e356-7 - PubMed
    1. Ann Thorac Surg. 1975 May;19(5):565-7 - PubMed
    1. Cardiol Young. 2015 Apr;25(4):698-704 - PubMed

MeSH terms