Abstract
A new method is presented for obtaining an analytical solution to the image-reconstruction problem in single-photon-emission computed tomography. The rigorous solution is introduced by applying an analytical continuation process to the two-dimensional Fourier transform of the image, which is derived from the one-dimensional Fourier transforms of projection functions. The calculations can be carried out in a short computation time without involving unstable procedures. Numerical simulations were made to demonstrate the effectiveness of the proposed method.
Similar articles
-
Exact fan-beam and 4pi-acquisition cone-beam SPECT algorithms with uniform attenuation correction.Med Phys. 2005 Nov;32(11):3440-7. doi: 10.1118/1.2068907. Med Phys. 2005. PMID: 16372416
-
A comparative study of attenuation correction algorithms in single photon emission computed tomography (SPECT).Eur J Nucl Med. 1987;13(2):55-62. doi: 10.1007/BF00256016. Eur J Nucl Med. 1987. PMID: 3497035
-
Image reconstruction--a tutorial.Comput Med Imaging Graph. 2001 Mar-Apr;25(2):97-103. doi: 10.1016/s0895-6111(00)00059-8. Comput Med Imaging Graph. 2001. PMID: 11137785 Review.
-
Iterative tomographic image reconstruction using Fourier-based forward and back-projectors.IEEE Trans Med Imaging. 2004 Apr;23(4):401-12. doi: 10.1109/TMI.2004.824233. IEEE Trans Med Imaging. 2004. PMID: 15084066
-
Iterative reconstruction algorithms in nuclear medicine.Comput Med Imaging Graph. 2001 Mar-Apr;25(2):105-11. doi: 10.1016/s0895-6111(00)00060-4. Comput Med Imaging Graph. 2001. PMID: 11137786 Review.
Cited by
-
A discrete convolution kernel for No-DC MRI.Inverse Probl. 2015 Aug;31(8):085006. doi: 10.1088/0266-5611/31/8/085006. Epub 2015 Jul 9. Inverse Probl. 2015. PMID: 28936022 Free PMC article.
-
A Fourier reconstruction algorithm with constant attenuation compensation using 180 degrees acquisition data for SPECT.Phys Med Biol. 2007 Oct 21;52(20):6165-79. doi: 10.1088/0031-9155/52/20/006. Epub 2007 Oct 1. Phys Med Biol. 2007. PMID: 17921578 Free PMC article.
-
Attenuation correction in cardiac positron emission tomography and single-photon emission computed tomography.J Nucl Cardiol. 1995 May-Jun;2(3):246-55. doi: 10.1016/s1071-3581(05)80062-5. J Nucl Cardiol. 1995. PMID: 9420795 Review.
-
An inversion formula for the exponential radon transform in spatial domain with variable focal-length fan-beam collimation geometry.Med Phys. 2006 Mar;33(3):792-8. doi: 10.1118/1.2170596. Med Phys. 2006. PMID: 16878581 Free PMC article.
-
An analytical algorithm for skew-slit collimator SPECT with uniform attenuation correction.Phys Med Biol. 2006 Dec 7;51(23):6199-211. doi: 10.1088/0031-9155/51/23/018. Epub 2006 Nov 9. Phys Med Biol. 2006. PMID: 17110780 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources