Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2016 Nov;24(4):222-232.
doi: 10.1177/1742271X16673124. Epub 2016 Oct 6.

The effectiveness of intrapartum ultrasonography in assessing cervical dilatation, head station and position: A systematic review and meta-analysis

Affiliations
Review

The effectiveness of intrapartum ultrasonography in assessing cervical dilatation, head station and position: A systematic review and meta-analysis

Yaw Amo Wiafe et al. Ultrasound. 2016 Nov.

Abstract

The objective of this review was to assess the effectiveness of intrapartum ultrasonography in measuring cervical dilatation, head station and position. Electronic literature searches were carried out of MEDLINE, CINAHL, and Web of Knowledge, plus manual reference list checks of all relevant articles. All published prospective studies comparing intrapartum ultrasonography with digital VE in the determination of cervical dilatation, head station and position were then evaluated for the success rate and level of agreement between ultrasonography and digital VE. Ultrasonography had higher success rate than digital VE in the determination of fetal head position, with a statistically significant difference in the first stage of labour. Second, although the successful determination of cervical dilatation was in favour of digital VE, the difference was not statistically significant. In addition, there was high agreement between ultrasound and digital VE findings on cervical dilatation. Lastly, a significant but moderate correlation between digital VE and ultrasound methods was found in the assessment of fetal head station. However, no meta-analysis could be done for the fetal head station due to the methodological differences between ultrasound anatomical landmarks and that of digital VE. The findings suggest that ultrasonography is superior to digital VE in the assessment of fetal head position, but has moderate correlation with digital VE in the assessment of head station. It also showed high agreement with digital VE in the assessment of cervical dilatation with no statistically significant difference in terms of success rate.

Keywords: Intrapartum; cervical dilatation; digital VE; head station; position; ultrasonography.

PubMed Disclaimer

Figures

Figure 1.
Figure 1.
PRISMA flow diagram.
Figure 2.
Figure 2.
Forest plot in favour of ultrasonography on the success rate of fetal head position determination in the first stage of labour.
Figure 3.
Figure 3.
Forest plot in favour of ultrasonography on the success rate of fetal head position determination in the second stage of labour.
Figure 4.
Figure 4.
Forest plot in favour of digital VE over ultrasonography on the success rate of the determination of cervical dilatation.
Figure 5.
Figure 5.
Cervical dilatation measurement.
Figure 6.
Figure 6.
The angle of progression measurement.
Figure 7.
Figure 7.
Head perineum distance measurement.

References

    1. Buchmann E, Libhaber E. Interobserver agreement in intrapartum estimation of fetal head station. Int J Gynaecol Obstet 2008; 101: 285–289. - PubMed
    1. Dixon L and Foureur M. The vaginal examination during labour. Is it of benefit or harm? In 11th International Conference on Control, Automation, Robotics and Visions. New Zealand College of Midwives (ICARCV) 2010.
    1. Eggebo TM. Ultrasound is the future diagnostic tool in active labor. Ultrasound Obstet Gynecol 2013; 41: 361–363. - PubMed
    1. Moher D, Liberati A, Tetzlaff J, et al. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Ann Intern Med 2009; 151: 264–269. - PubMed
    1. Wilkins T, Gillies RA, Davies K. EMBASE versus MEDLINE for family medicine searches: can MEDLINE searches find the forest or a tree? Can Fam Phys 2005; 51: 848–849. - PMC - PubMed

LinkOut - more resources