Accuracy of saline contrast sonohysterography in detection of endometrial polyps and submucosal leiomyomas in women of reproductive age with abnormal uterine bleeding: systematic review and meta-analysis
- PMID: 27862503
- DOI: 10.1002/uog.17352
Accuracy of saline contrast sonohysterography in detection of endometrial polyps and submucosal leiomyomas in women of reproductive age with abnormal uterine bleeding: systematic review and meta-analysis
Abstract
Objective: To analyze the diagnostic accuracy of two- (2D) and three- (3D) dimensional saline contrast sonohysterography (SCSH) in the detection of endometrial polyps and submucosal uterine leiomyomas in women of reproductive age with abnormal uterine bleeding compared with gold standard hysteroscopy.
Methods: A systematic review of diagnostic studies that compared 2D- and/or 3D-SCSH with hysteroscopy and anatomopathology was conducted according to PRISMA and SEDATE recommendations. The databases MEDLINE, EMBASE and The Cochrane Library were searched electronically using specific terms with no restriction on language or publication year. Quality assessment of included studies was performed using the QUADAS-2 tool. Meta-analysis was performed with the Meta-DiSk program and data presented as forest plots and summary receiver-operating characteristics (SROC) curves. Pooled sensitivity, specificity and positive (LR+) and negative (LR-) likelihood ratios of SCSH in the detection of uterine cavity abnormalities were calculated.
Results: A total of 1398 citations were identified and five studies were included in the systematic review and meta-analysis. Pooled sensitivity and specificity of 2D-SCSH in detecting endometrial polyps were 93% (95% CI, 89-96%) and 81% (95% CI, 76-86%), respectively, with pooled LR+ of 5.41 (95% CI, 2.60-11.28) and LR- of 0.10 (95% CI, 0.06-0.17). In the detection of submucosal uterine leiomyomas, pooled sensitivity and specificity were 94% (95% CI, 89-97%) and 81% (95% CI, 76-86%), respectively, with pooled LR+ of 4.25 (95% CI, 2.20-8.21) and LR- of 0.11 (95% CI, 0.05-0.22). 2D-SCSH had good accuracy in detecting endometrial polyps and submucosal uterine leiomyomas, with areas under the SROC curves of 0.97 ± 0.02 and 0.97 ± 0.03, respectively. Studies that analyzed the diagnostic accuracy of 3D-SCSH could not be compared due to high heterogeneity related to menopausal status, type of technique used and primary outcome being investigation of infertility.
Conclusions: 2D-SCSH proved to be a highly sensitive method for detection of endometrial polyps and submucosal uterine leiomyomas, making it a potential first-line diagnostic method in the work-up for women with abnormal uterine bleeding. More studies are needed on 3D-SCSH in women of reproductive age. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Keywords: abnormal uterine bleeding; hysteroscopy; saline infusion sonography; ultrasonography; uterus.
Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Similar articles
-
Three-dimensional saline infusion sonography compared to two-dimensional saline infusion sonography for the diagnosis of focal intracavitary lesions.Cochrane Database Syst Rev. 2017 May 5;5(5):CD011126. doi: 10.1002/14651858.CD011126.pub2. Cochrane Database Syst Rev. 2017. PMID: 28472862 Free PMC article.
-
Imaging for Polyps and Leiomyomas in Women With Abnormal Uterine Bleeding: A Systematic Review.Obstet Gynecol. 2016 Dec;128(6):1425-1436. doi: 10.1097/AOG.0000000000001776. Obstet Gynecol. 2016. PMID: 27824761
-
Diagnostic accuracy of saline contrast sonohysterography in detecting endometrial polyps in women with postmenopausal bleeding: systematic review and meta-analysis.Ultrasound Obstet Gynecol. 2019 Jul;54(1):28-34. doi: 10.1002/uog.20229. Epub 2019 Jun 12. Ultrasound Obstet Gynecol. 2019. PMID: 30693579
-
Diagnostic accuracy of saline infusion sonography in the evaluation of uterine cavity abnormalities prior to assisted reproductive techniques: a systematic review and meta-analyses.Hum Reprod Update. 2015 Mar-Apr;21(2):262-74. doi: 10.1093/humupd/dmu057. Epub 2014 Dec 10. Hum Reprod Update. 2015. PMID: 25505226
-
Saline contrast hysterosonography in abnormal uterine bleeding: a systematic review and meta-analysis.BJOG. 2003 Oct;110(10):938-47. doi: 10.1111/j.1471-0528.2003.02472.x. BJOG. 2003. PMID: 14550365
Cited by
-
Diagnostic value of three-dimensional saline infusion sonohysterography in the evaluation of the uterus and uterine cavity lesions.Pol J Radiol. 2018 Nov 30;83:e482-e490. doi: 10.5114/pjr.2018.80132. eCollection 2018. Pol J Radiol. 2018. PMID: 30655928 Free PMC article. Review.
-
Tailoring the Diagnostic Pathway for Medical and Surgical Treatment of Uterine Fibroids: A Narrative Review.Diagnostics (Basel). 2024 Sep 14;14(18):2046. doi: 10.3390/diagnostics14182046. Diagnostics (Basel). 2024. PMID: 39335725 Free PMC article. Review.
-
Review of magnetic resonance-guided focused ultrasound in the treatment of uterine fibroids.Clinics (Sao Paulo). 2017 Oct;72(10):637-641. doi: 10.6061/clinics/2017(10)08. Clinics (Sao Paulo). 2017. PMID: 29160427 Free PMC article. Review.
-
Sonoelastography evaluation in the diagnosis of endometrial pathology combined with chronic endometritis in infertile women.J Med Life. 2022 Mar;15(3):397-404. doi: 10.25122/jml-2021-0358. J Med Life. 2022. PMID: 35450000 Free PMC article.
-
Diagnosis and Management of Infertility: A Review.JAMA. 2021 Jul 6;326(1):65-76. doi: 10.1001/jama.2021.4788. JAMA. 2021. PMID: 34228062 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical