Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2017 Feb:98:881.e1-881.e4.
doi: 10.1016/j.wneu.2016.11.028. Epub 2016 Nov 17.

Ventral Dural Injury After Oblique Lumbar Interbody Fusion

Affiliations
Case Reports

Ventral Dural Injury After Oblique Lumbar Interbody Fusion

JaeChil Chang et al. World Neurosurg. 2017 Feb.

Abstract

Background: Oblique lumbar interbody fusion (OLIF) through the oblique corridor between the aorta and anterior border of psoas muscle is favored among spinal surgeons who employ minimally invasive techniques. We report a case of ventral dural tear after OLIF that was associated with the inaccurate trajectory direction of endplate preparation. This is the first report to our knowledge of ventral dural tear associated with OLIF.

Case description: A 72-year-old woman presented with right leg pain and numbness. X-rays showed degenerative spondylolisthesis and loss of disc height at L4-L5 and L5-S1 levels. Magnetic resonance imaging revealed right-sided paracentral disc herniation at the L3-L4 level and foraminal disc herniation at L4-L5. The initial surgical plan was OLIF of L3-L4 and L4-L5 after percutaneous screw fixation without laminectomy. With the patient in the lateral position, discectomy and endplate preparation were done successfully at the L3-L4 level, and the same procedure was done at the L4-L5 level for OLIF. A sharp Cobbs elevator for endplate preparation triggered a ventral dural defect at the L4-L5 level. We changed the patient's position to attempt dural repair. The ventral dural defect could not be repaired because it was too large. After the herniated rootlets were repositioned, TachoComb was patched over the defect site. Postoperatively, the patient has no definite neurologic deficits.

Conclusions: When a surgeon performs OLIF, ventral dural injury should be avoided during the procedure of endplate preparation and contralateral annular release.

Keywords: Complication; OLIF; Ventral dural injury.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources