Effect of spatial resolution on SPECT quantification values
- PMID: 2786945
Effect of spatial resolution on SPECT quantification values
Abstract
The effect of spatial resolution on quantification by single photon emission computed tomography (SPECT) was studied using a rotating gamma camera and 99mTc. Using phantoms with hot and cold regions, experiments were performed to ascertain relationships between the source and the SPECT image, and to compare them with theoretic calculations. According to the results, the SPECT value represented the true radioactivity when the objects' sizes were 2.5 times larger than full width at half maximum (FWHM) for hot regions. For cold regions, there were errors of approximately 20% for the true value, even in the case of such large sizes. In addition, sizes at half maximum images corresponded to true object sizes when hot region sizes were larger than 1.4 x FWHM. The relationship between absolute radioactivity and total SPECT value was linear when the threshold level was zero. Knowing the effect of spatial resolution is a necessity in clinical SPECT studies.
Similar articles
-
A dual modality approach to quantitative quality control in emission tomography.Phys Med Biol. 2005 Aug 7;50(15):N187-94. doi: 10.1088/0031-9155/50/15/N03. Epub 2005 Jul 19. Phys Med Biol. 2005. PMID: 16030376
-
Treatment of Compton scattering in maximum-likelihood, expectation-maximization reconstructions of SPECT images.J Nucl Med. 1991 Jun;32(6):1285-91. J Nucl Med. 1991. PMID: 2045948
-
Evaluation of high-resolution pinhole SPECT using a small rotating animal.J Nucl Med. 2001 Dec;42(12):1863-9. J Nucl Med. 2001. PMID: 11752086
-
Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system.J Nucl Med. 2005 May;46(5):868-77. J Nucl Med. 2005. PMID: 15872362 Clinical Trial.
-
Small animal imaging with multi-pinhole SPECT.Methods. 2009 Jun;48(2):83-91. doi: 10.1016/j.ymeth.2009.03.015. Epub 2009 Mar 26. Methods. 2009. PMID: 19328232 Review.
Cited by
-
Sex-specific reference limits of left ventricular ejection fraction and volumes estimated by gated myocardial perfusion imaging for low-risk patients in China: a comparison between three quantitative algorithms.Quant Imaging Med Surg. 2022 Jan;12(1):144-158. doi: 10.21037/qims-21-347. Quant Imaging Med Surg. 2022. PMID: 34993067 Free PMC article.
-
Imaging heterogeneity of peptide delivery and binding in solid tumors using SPECT imaging and MRI.EJNMMI Res. 2016 Dec;6(1):3. doi: 10.1186/s13550-016-0160-4. Epub 2016 Jan 14. EJNMMI Res. 2016. PMID: 26769345 Free PMC article.
-
Progression of dopamine transporter decline in patients with the Parkinson variant of multiple system atrophy: a voxel-based analysis of [123I]β-CIT SPECT.Eur J Nucl Med Mol Imaging. 2012 Jun;39(6):1012-20. doi: 10.1007/s00259-012-2100-5. Epub 2012 Mar 30. Eur J Nucl Med Mol Imaging. 2012. PMID: 22460689
-
Effects of non-linear flow and spatial orientation on technetium-99m hexamethylpropylene amine oxime single-photon emission tomography.Eur J Nucl Med. 1995 Sep;22(9):1009-16. doi: 10.1007/BF00808412. Eur J Nucl Med. 1995. PMID: 7588937
-
Feasibility study of multi Laue lens based SPECT with a dedicated 3D reconstruction algorithm using Monte Carlo simulations.Sci Rep. 2025 Apr 17;15(1):13339. doi: 10.1038/s41598-025-85955-7. Sci Rep. 2025. PMID: 40246994 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources