Current rare indications and future directions for implantable loop recorders
- PMID: 27873022
- DOI: 10.1007/s00399-016-0475-x
Current rare indications and future directions for implantable loop recorders
Abstract
The scope of application for implantable loop recorders has shifted away from the evaluation of unclear palpitations and syncope episodes to more complex conditions. This article focuses on rare indications of growing importance such as rhythm monitoring after ablation of atrial fibrillation or after cryptogenic stroke. Furthermore, forthcoming applications in various clinical settings are described, e. g., arrhythmia detection after myocardial infarction, after catheter-based valve interventions, in heart failure, and in cardiomyopathies. Enhancement of the capabilities of implantable loop recorders could broaden their fields of use.
Keywords: Atrial fibrillation; Electrocardiography monitoring, ambulatory; Implantable loop recorder; Stroke; Syncope.
Similar articles
-
[Implantable loop recorders in the diagnosis of syncope].Herzschrittmacherther Elektrophysiol. 2016 Dec;27(4):345-350. doi: 10.1007/s00399-016-0476-9. Herzschrittmacherther Elektrophysiol. 2016. PMID: 27812742 Review. German.
-
[Implantable loop recorder BioMonitor 2 (Biotronik)].Herzschrittmacherther Elektrophysiol. 2016 Dec;27(4):337-340. doi: 10.1007/s00399-016-0469-8. Epub 2016 Nov 15. Herzschrittmacherther Elektrophysiol. 2016. PMID: 27848030 Review. German.
-
[Implantable loop recorders of the Reveal family (Medtronic)].Herzschrittmacherther Elektrophysiol. 2016 Dec;27(4):333-336. doi: 10.1007/s00399-016-0467-x. Epub 2016 Nov 22. Herzschrittmacherther Elektrophysiol. 2016. PMID: 27878365 Review. German.
-
[Indications for implantable loop recorders in patients with channelopathies and ventricular tachycardias].Herzschrittmacherther Elektrophysiol. 2016 Dec;27(4):360-365. doi: 10.1007/s00399-016-0474-y. Herzschrittmacherther Elektrophysiol. 2016. PMID: 27844191 Review. German.
-
[Implantable loop recorder of the Confirm family (St. Jude Medical)].Herzschrittmacherther Elektrophysiol. 2016 Dec;27(4):341-344. doi: 10.1007/s00399-016-0468-9. Epub 2016 Nov 7. Herzschrittmacherther Elektrophysiol. 2016. PMID: 27822592 Review. German.
Cited by
-
Diagnostic yield of an insertable cardiac monitor in a large patient population.Heart Rhythm O2. 2022 Nov 24;4(2):97-102. doi: 10.1016/j.hroo.2022.11.005. eCollection 2023 Feb. Heart Rhythm O2. 2022. PMID: 36873314 Free PMC article.
-
New-generation miniaturized insertable cardiac monitor with a long sensing vector: Insertion procedure, sensing performance, and home monitoring transmission success in a real-world population.Heart Rhythm O2. 2022 Jan 30;3(2):152-159. doi: 10.1016/j.hroo.2022.01.010. eCollection 2022 Apr. Heart Rhythm O2. 2022. PMID: 35496450 Free PMC article.
-
Clinical evaluation of a small implantable cardiac monitor with a long sensing vector.Pacing Clin Electrophysiol. 2019 Jul;42(7):1038-1046. doi: 10.1111/pace.13728. Epub 2019 Jun 5. Pacing Clin Electrophysiol. 2019. PMID: 31119745 Free PMC article.
-
The BIOMONITOR III Injectable Cardiac Monitor: Clinical Experience with a Novel Injectable Cardiac Monitor.J Clin Med. 2022 Mar 16;11(6):1634. doi: 10.3390/jcm11061634. J Clin Med. 2022. PMID: 35329960 Free PMC article.
-
Analysis of the determining factors of detectable P-wave and amplitude of QRS complex sensed by implantable loop recorder.J Arrhythm. 2021 Jun 24;37(4):1069-1076. doi: 10.1002/joa3.12582. eCollection 2021 Aug. J Arrhythm. 2021. PMID: 34386134 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical