Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1989 Jul;14(7):484-91.
doi: 10.1097/00003072-198907000-00004.

Enhanced sensitivity and specificity of thallium-201 imaging for the detection of regional ischemic coronary disease by combining SPECT with "bull's eye" analysis

Affiliations
Comparative Study

Enhanced sensitivity and specificity of thallium-201 imaging for the detection of regional ischemic coronary disease by combining SPECT with "bull's eye" analysis

B Kasabali et al. Clin Nucl Med. 1989 Jul.

Abstract

Previous studies have indicated that the combination of single photon emission computed tomography (SPECT) and quantitative "bull's eye" analysis (QBA) TI-201 cardiac stress imaging may improve the detection of myocardial ischemia over that achieved with planar (PLN) imaging. This study will evaluate the sensitivity and specificity of SPECT and QBA in the detection of disease in the left anterior descending (LAD), left circumflex (LCX), and right coronary artery. Ninety-nine patients who underwent both TI-201 stress imaging and coronary arteriography were evaluated retrospectively. Of the 99, 62 had PLN imaging and 37 were evaluated with SPECT; 23 of these 37 had QBA. The overall sensitivity and specificity were as follows: PLN, 94% and 50%; SPECT, 90% and 67%; QBA, 100% and 20%; and SPECT with QBA, 92% and 72%, respectively. The regional sensitivity and specificity of PLN for individual coronary arteries were as follows: RCA, 78% and 74%; LAD, 89% and 60%; LCX, 50% and 89%, respectively. For SPECT, the results were: RCA, 86% and 93%; LAD, 85% and 88%; and LCX, 60% and 88%. For QBA alone, the results were: RCA, 100% and 75%; LAD, 88% and 53%; and LCX, 100% and 89%. The results for QBA with SPECT were: RCA, 100% and 94%; LAD, 88% and 80%; and LCX, 67% and 95%. Thus, SPECT interpreted on conjunction with QBA showed higher sensitivity for evaluation of ischemia in the RCA and LCX arteries and higher specificity in the detection of LAD and RCA disease than did PLN TI-201 imaging. Because of the low specificity of QBA (20%), caution is advised in the interpretation of QBA alone without reviewing SPECT images.

PubMed Disclaimer

Similar articles

Publication types

Substances

LinkOut - more resources