. 2017 Feb;33(2):144-151.
doi: 10.1016/j.dental.2016.11.006. Epub 2016 Nov 24.

Effect of cement space on stress distribution in Y-TZP based crowns

Affiliations

Effect of cement space on stress distribution in Y-TZP based crowns

Carlos Eduardo Edwards Rezende et al. Dent Mater. 2017 Feb.

Abstract

Objective: To evaluate the stress distribution in bi-layered Y-TZP based crowns, according to the occlusal internal spacing between coping and abutment.

Methods: Twelve premolar shaped Y-TZP copings were made by a CAD/CAM system and seated on an abutment to evaluate the internal fit at the occlusal third using micro-CT images. Considering the fitting range obtained experimentally, two 3D finite element models, consisting on bone tissue, a titanium implant, a zirconia abutment, cement layer and a bi-layered Y-TZP ceramic crown were constructed based on the micro-CT images, one corresponding to the thinnest cement space and other representing the specimen with the thickest cement space obtained experimentally. A 250N axial load was applied at the center of the occlusal surface of the crown (≅0,8mm2 area) and the first principal stress distribution was plotted and analyzed.

Results: The greatest maximum principal stress occurred within the veneer ceramic right below the site of loading. The thickest cement model showed higher stress concentration at the center of occlusal surface of veneer and the center of occlusal internal surface of coping.

Significance: Knowledge of stress distribution in ceramic crowns with different cement thicknesses will help clinicians to properly adjust crown fit, in seeking to avoid porcelain fractures.

Keywords: CAD–CAM; Cement thickness; Ceramic crowns; Ceramic restorative materials; Finite element analysis; Fit; Micro-CT; Zirconia.