Clinical Trial
. 2017 Mar;33(3):431-439.
doi: 10.1007/s10554-016-1018-6. Epub 2016 Nov 28.

Accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography

Affiliations
Clinical Trial

Accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography

Carlos Collet et al. Int J Cardiovasc Imaging. 2017 Mar.

Abstract

To establish the accuracy of coronary computed tomography angiography (CTA) for in-scaffold quantitative evaluation with optical coherence tomography (OCT) as a reference. The translucent backbone of the bioresorbable scaffold allow us to evaluate non-invasively the coronary lumen with coronary CTA. In the ABSORB first-in-man studies, coronary CTA was shown to be feasible for quantitative luminal assessment. Nevertheless, a comparison with an intravascular modality with higher resolution has never been performed. In the ABSORB Cohort B trial, 101 patient with non-complex lesions were treated with the fully biodegradable vascular scaffold. For this analysis, all patients who underwent coronary CTA at 18 months and OCT within ±180 days were included. Coronary CTA and OCT data were analysed at an independent core laboratory for quantitative cross-sectional luminal dimensions. The primary objective was the accuracy and precision of coronary CTA for in-scaffold minimal lumen area assessment, with OCT as a reference. Among the 101 patients of the ABSORB Cohort B trial, 35 underwent both OCT and coronary CTA. The feasibility of quantitative evaluation was 74%. In the scaffolded segment, coronary CTA underestimated minimal lumen area by 9.8% (accuracy 0.39 mm2, precision 1.0 mm2, 95% limits of agreement -1.71 to 2.50 mm2). A similar level of agreement was observed in the non-scaffolded segment. Compared to OCT, coronary CTA appears to be accurate for the estimation of in-scaffold luminal areas, with no difference compared to the non-scaffolded region.

Keywords: Coronary computed tomography angiography; Optical coherence tomography; Polymeric scaffolds.

PubMed Disclaimer

References

    1. JACC Cardiovasc Interv. 2013 Mar;6(3):228-36 - PubMed
    1. J Am Coll Cardiol. 2013 Nov 5;62(19):1813-4 - PubMed
    1. Circulation. 2011 Feb 22;123(7):779-97 - PubMed