Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Apr;7(4):399-404.
doi: 10.1002/alr.21887. Epub 2016 Nov 29.

Development and validation of a septoplasty training model using 3-dimensional printing technology

Affiliations

Development and validation of a septoplasty training model using 3-dimensional printing technology

Mahmoud A AlReefi et al. Int Forum Allergy Rhinol. 2017 Apr.

Abstract

Background: Providing alternative training modalities may improve trainees' ability to perform septoplasty. Three-dimensional printing has been shown to be a powerful tool in surgical training. The objectives of this study were to explain the development of our 3-dimensional (3D) printed septoplasty training model, to assess its face and content validity, and to present evidence supporting its ability to distinguish between levels of surgical proficiency.

Methods: Imaging data of a patient with a nasal septal deviation was selected for printing. Printing materials reproducing the mechanical properties of human tissues were selected based on literature review and prototype testing. Eight expert rhinologists, 6 senior residents, and 6 junior residents performed endoscopic septoplasties on the model and completed a postsimulation survey. Performance metrics in quality (final product analysis), efficiency (time), and safety (eg, perforation length, nares damage) were recorded and analyzed in a study-blind manner.

Results: The model was judged to be anatomically correct and the steps performed realistic, with scores of 4.05 ± 0.82 and 4.2 ± 1, respectively, on a 5-point Likert scale. Ninety-two percent of residents desired the simulator to be integrated into their teaching curriculum. There was a significant difference (p < 0.05) between the expert, intermediate, and novice groups in time taken and nares cuts, whereas other performance metrics showed no significant difference.

Conclusion: To our knowledge, there are no other simulator training models for septoplasty. Our model incorporates 2 different materials mixed into the 3 relevant consistencies necessary to simulate septoplasty. Our findings provide evidence supporting the validity of the model.

Keywords: 3D printing; education; endoscopic; model; nasal septal deviation; rhinology; septoplasty; simulation; training; validation.

PubMed Disclaimer

Publication types

LinkOut - more resources