[Investigating the clinical applicability of EBT2 self-developing films]
- PMID: 27898748
[Investigating the clinical applicability of EBT2 self-developing films]
Abstract
The purpose of the study was to investigate the physical properties of the EBT2 radiochromic films and define the conditions of its clinical applicability. We irradiated the films with different treatment techniques 3D conformal (3DCRT), intensity-modulated (IMRT) and stereotactic body radiotherapy with arc therapy (SBRT), and then compared the data with the dose distribution exported from the treatment planning system (Eclipse). Two film analysis softwares were investigated for the comparison: PTW Mephysto and FilmQA Pro. The comparisons of dose distributions were performed with gamma analysis, and the gamma criterion was 3%, 3mm, and 2%, 2mm. The gamma analysis results by the two programs were the following, (PTW/FilmQA Pro) with 3%, 3mm gamma criterion: 3DCRT (95,5/100%), IMRT (97/99,9%), SBRT (99,7/100%). In case of 2%, 2mm the results were: 3DCRT (87,1/98,9%), IMRT (92/98,5%), SBRT (96,7/97,9%). Based on the results it can be stated that during proper use, the features of the scanner do not affect the results. Both evaluation softwares are suitable for calibrating and evaluating films, moreover, performing the gamma analysis. The EBT2 film is suitable for the two-dimensional controlling of radiation therapy plans.
Vizsgálatunk célja az EBT2 önhívó filmek fizikai tulajdonságainak megismerése és klinikai alkalmazási feltételeinek meghatározása volt. A filmeket különbözõ technikával készült tervek alapján (3D konformális – 3DCRT, intenzitásmodulált – IMRT és sztereotaxiás – SBRT) technikával sugaraztuk be, majd összehasonlítottuk a tervezõrendszerbõl exportált dóziseloszlással. Az elemzéshez két különbözõ gyártó filmelemzõ szoftverét használtuk: PTW Mephysto és FilmQA Pro. A tervek összehasonlítását gamma-analízissel végeztük, 3%, 3 mm-es, illetve 2%, 2 mm-es gamma-kritériumra. PTW Mephysto, illetve FilmQA Pro szoftverrel végzett gamma-analízis eredményei 3%, 3 mm-es feltételekre: 3DCRT (95,5/100%), IMRT (97/99,9%), SBRT (99,7/100%). A 2%, 2 mm-es gamma-kritérium esetén 3DCRT (87,1/98,9%), IMRT (92/98,5%), SBRT (96,7/97,9%) eredményeket kaptunk. Megállapítható, hogy megfelelõ használat mellett a szkenner tulajdonságai nem befolyásolják az eredményeket. Mindkét kiértékelõ szoftver alkalmas a filmek kalibrálására, kiértékelésére. Az EBT2 önhívó film alkalmas a sugárterápiás tervek kétdimenziós ellenõrzésére.
Similar articles
-
Comparison of three film analysis softwares using EBT2 and EBT3 films in radiotherapy.Radiol Oncol. 2020 Aug 5;54(4):505-512. doi: 10.2478/raon-2020-0049. Radiol Oncol. 2020. PMID: 32889796 Free PMC article.
-
Comparison of Gafchromic EBT2 and EBT3 for patient-specific quality assurance: cranial stereotactic radiosurgery using volumetric modulated arc therapy with multiple noncoplanar arcs.Med Phys. 2013 Aug;40(8):082105. doi: 10.1118/1.4816300. Med Phys. 2013. PMID: 23927342
-
Comparison of spinal Stereotactic Body Radiotherapy (SBRT) planning techniques: intensity-modulated radiation therapy, modulated arc therapy, and helical tomotherapy.Med Dosim. 2017 Autumn;42(3):210-215. doi: 10.1016/j.meddos.2017.04.001. Epub 2017 May 16. Med Dosim. 2017. PMID: 28526192
-
A comparison of three-film analysis software for stereotactic radiotherapy patient-specific quality assurance.J Appl Clin Med Phys. 2024 Mar;25(3):e14203. doi: 10.1002/acm2.14203. Epub 2023 Nov 8. J Appl Clin Med Phys. 2024. PMID: 37937814 Free PMC article.
-
Volumetric arc intensity-modulated therapy for spine body radiotherapy: comparison with static intensity-modulated treatment.Int J Radiat Oncol Biol Phys. 2009 Dec 1;75(5):1596-604. doi: 10.1016/j.ijrobp.2009.05.005. Epub 2009 Sep 3. Int J Radiat Oncol Biol Phys. 2009. PMID: 19733447
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources