A Meta-analysis of Functional Outcomes in Patient-Specific Instrumented Knee Arthroplasty
- PMID: 27907935
- DOI: 10.1055/s-0036-1593869
A Meta-analysis of Functional Outcomes in Patient-Specific Instrumented Knee Arthroplasty
Abstract
Alignment data in patient-specific instrumented (PSI) knee arthroplasty have been examined in several meta-analyses, with demonstration of comparative but not improved restitution of a neutral mechanical axis and favorable outcomes in femoral implant axial alignment. To date, no comprehensive synthesis of data has been conducted specifically for functional outcomes. Relevant databases were searched according to Preferred Reporting Items for Systematic reviews and Meta-analyses guidelines during the period 2000 to 2015 of Levels 1 and 2 studies comparing functional outcomes of patient-specific instrumentation (PSI) versus conventional instrumentation. Outcomes of interest included postoperative Knee Society score (KSS) (function), KSS (knee), range of movement (ROM), Oxford knee scores (OKS), and Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores. Five randomized controlled trials and three prospective-comparative studies were included reporting on a total of 828 knees. All eight studies reported postoperative KSS (function) and seven studies reported KSS (knee). Three studies reported postoperative OKS, four documented ROM, and two reported WOMAC scores. Meta-analysis demonstrated equivalent KSS (function) scores 3 months postsurgery (Z = 1.71, p = 0.09). In addition, no significant differences were found for KSS (function) at 6 months (Z = 0.51, p = 0.61) or 12 to 24 months postsurgery (Z = 0.05, p = 0.96). In addition, no significant differences were found between PSI and conventional instrumentation for postoperative KSS (knee), ROM, or OKS. In summary, this systematic review and meta-analysis demonstrates no conclusive evidence for or against PSI when considering short-term functional outcomes. Further high-quality studies are required to investigate both mid- and long-term outcomes as well as survivorship data.
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Conflict of interest statement
Disclosure The authors report no conflicts of interest in this work.
Similar articles
-
Functional outcomes in patient specific instrumentation vs. conventional instrumentation for total knee arthroplasty; a systematic review and meta-analysis of prospective studies.BMC Musculoskelet Disord. 2022 Jul 23;23(1):702. doi: 10.1186/s12891-022-05620-2. BMC Musculoskelet Disord. 2022. PMID: 35870913 Free PMC article.
-
Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA.Knee Surg Sports Traumatol Arthrosc. 2016 Jan;24(1):102-11. doi: 10.1007/s00167-014-3345-2. Epub 2014 Oct 19. Knee Surg Sports Traumatol Arthrosc. 2016. PMID: 25326759
-
Outcome of kinematic alignment using patient-specific instrumentation versus mechanical alignment in TKA: a meta-analysis and subgroup analysis of randomised trials.Arch Orthop Trauma Surg. 2018 Sep;138(9):1293-1303. doi: 10.1007/s00402-018-2988-8. Epub 2018 Jun 30. Arch Orthop Trauma Surg. 2018. PMID: 29961093
-
The John Insall Award: No Functional Benefit After Unicompartmental Knee Arthroplasty Performed With Patient-specific Instrumentation: A Randomized Trial.Clin Orthop Relat Res. 2016 Jan;474(1):60-8. doi: 10.1007/s11999-015-4259-0. Clin Orthop Relat Res. 2016. PMID: 25791446 Free PMC article. Clinical Trial.
-
Clinical and Patient-Reported Outcomes of Medial Stabilized Versus Non-Medial Stabilized Prostheses in Total Knee Arthroplasty: A Systematic Review and Meta-Analysis.J Arthroplasty. 2021 Feb;36(2):767-776.e2. doi: 10.1016/j.arth.2020.07.086. Epub 2020 Aug 8. J Arthroplasty. 2021. PMID: 32978025
Cited by
-
Customized-individually-made origin® implants in total knee arthroplasty allow a reliable solution for accurate reproduction of planned implant positioning.J Exp Orthop. 2023 Nov 28;10(1):123. doi: 10.1186/s40634-023-00706-9. J Exp Orthop. 2023. PMID: 38015319 Free PMC article.
-
Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial.Knee Surg Sports Traumatol Arthrosc. 2018 Jun;26(6):1792-1799. doi: 10.1007/s00167-017-4792-3. Epub 2017 Nov 28. Knee Surg Sports Traumatol Arthrosc. 2018. PMID: 29181560 Clinical Trial.
-
Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis.BMC Musculoskelet Disord. 2019 Nov 23;20(1):561. doi: 10.1186/s12891-019-2940-2. BMC Musculoskelet Disord. 2019. PMID: 31759392 Free PMC article.
-
Clinical outcomes after using patient specific instrumentation: is it worth the effort? A minimum 5-year retrospective review of 298 PSI knees.Arch Orthop Trauma Surg. 2023 Jun;143(6):3409-3422. doi: 10.1007/s00402-022-04593-0. Epub 2022 Oct 10. Arch Orthop Trauma Surg. 2023. PMID: 36214876 Free PMC article.
-
Funding has no effect on clinical outcomes of total joint arthroplasty emerging technologies: a systematic review of bibliometrics and conflicts of interest.Arthroplasty. 2022 Nov 1;4(1):45. doi: 10.1186/s42836-022-00146-3. Arthroplasty. 2022. PMID: 36316729 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical