Jet outflow and open field line measurements on the C-2U advanced beam-driven field-reversed configuration plasma experiment
- PMID: 27910352
- DOI: 10.1063/1.4960059
Jet outflow and open field line measurements on the C-2U advanced beam-driven field-reversed configuration plasma experiment
Abstract
Knowledge and control of the axial outflow of plasma particles and energy along open-magnetic-field lines are of crucial importance to the stability and longevity of the advanced beam-driven field-reversed configuration plasma. An overview of the diagnostic methods used to perform measurements on the open field line plasma on C-2U is presented, including passive Doppler impurity spectroscopy, microwave interferometry, and triple Langmuir probe measurements. Results of these measurements provide the jet ion temperature and axial velocity, electron density, and high frequency density fluctuations.
LinkOut - more resources
Full Text Sources
Other Literature Sources